Page 23
WATERAX
STRIKER-2/3 Owner's Manual
04/2015
23
STRIKER-2/3 Wiring
Standard WATERAX wiring configuration:
All vehicle STRIKER pumps are wired from the factory to work with an XCP control panel. To revert to the
original engine controls, refer to the next section for instructions.
XCP vs. Engine Controls:
A
WATERAX
XCP control panel cannot be operated simultaneously with the original engine controls;
undesired behaviors may occur. It is recommended to remove the key switch from the engine and store it
in a safe location if equipped with an XCP.
Original Engine Wiring Configuration:
To revert back to the Original Engine Controls refer to the instructions below.
ENGINES
FOR XCP
FOR ENGINE CONTROLS
HO
NDA G
X3
90 13 H
P
Disconnect the four FASTWIRE Magneto Ground
Wires and connect the Ignition Coil Wires. Black with
Black and Red with Red.
Disconnect FASTWIRE Low Oil Wire from the Low
Oil Pressure Switch and connect the Engine Controls
Low Oil Wire. Secure the remaining wire.
Engine
Ignition Coil
Wires
FASTWIRE Magneto
Ground Wires
Engine Low
Oil Wire
Low Oil
Pressure
Switch
FASTWIRE
Low Oil Wire