Installation and Service Manual – Under-the-Counter Point of Use 6 Stage Reverse Osmosis System with Pump & UV 

 

Copyright © 2020 WaterAnywhere. 

All Rights Reserved.

 

Page 19 

 

 

UV System Operation Safety 

 

  D A N G E R  

 

Failure to follow these instructions will result in serious injury or death. 

 

Electric Shock:

 To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a 

situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, 
refer to an authorized service facility. 

 

GROUNDING:

 This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric 

current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. 
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 
Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with this system – if it does not fit in the 
outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this system. 

 

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

: To comply with the National Electrical Code (NFPA 70) and to provide additional 

protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 
30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule. 

 

DO NOT operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any 
manner. 

 

DO NOT use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by 
the manufacturer / distributor may cause an unsafe condition. 

 

DO NOT install this disinfection system where it will be exposed to the weather or to temperatures below freezing. 

 

DO NOT store this disinfection system where it will be exposed to the weather. 

 

DO NOT store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the 
water supply has been disconnected.

 

  W A R N I N G

 

 

During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is 
recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time.  

 

Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing 
under-treated water that may, in rare instances, pose health hazards. 

 

This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system 
may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin. 

 

Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void 
the manufacturer's warranty 

 

PROP 65 WARNING: This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, 
and mercury, which is known to the State of California

 to cause birth defects or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov. 

  C A U T I O N

 

Failure to follow these instructions could result in minor or moderate injury. 

 

Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the 
controller or lamp connector. 

 

Due to thermal expansion concerns and potential material degradation due to UV exposer, it is recommended to use metal fittings and at least 10” 
of copper pipe on the outlet of your UV chamber. 

 

 Hg EXPOSURE: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes 
and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for 
the removal and disposal of mercury waste.

 

N O T I C E

 

 

The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the 
UV lamp annually. 

 

The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, are also not to handle the UV system unless they have been given supervision or instruction. 

 

EXTENSION CORDS: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord 
connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an 
electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise 
caution when arranging the cord so that it will not be tripped over or pulled. Do not use damaged extension cords. Examine extension cord before 
using and replace if damaged. Do not abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the 
extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always 
grasp the plug and pull to disconnect. 

 

 If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. 

 

SYSTEM PROTECTION:

 To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly 

recommended. 

 

The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, 
Chapter 1, Subchapter J, Radiological Health. 

 

Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.

 

 

 

Summary of Contents for AAA-RO50PUVW

Page 1: ...om 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 6 Stage Point of Use RO UV Drinking Water System with Pump Document ID AAAROPUVW Revision 05 13 20 AAA RO50...

Page 2: ...he RO membrane the heart of the RO system substantially reduces the total dissolved solids TDS from the water including arsenic barium cadmium chromium hexavalent chromium trivalent copper turbidity f...

Page 3: ...ifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step 3 Drain Saddle Installation 9 Step 4 Syste...

Page 4: ...e of a water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologic...

Page 5: ...ng D Housing with the RO Membrane E Tank Shut Off Valve F Four way Valve G In Line Cartridge with Activated Carbon H Flow Restrictor I Tank Valve J Tank K UV System L Faucet 1 Clean Water Outlet 2 Pol...

Page 6: ...pplies UV Controller should be mounted to the wall see System Mounting section Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system...

Page 7: ...ings and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cau...

Page 8: ...t surface at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires...

Page 9: ...p or sink top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by...

Page 10: ...e Starting with the drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not dril...

Page 11: ...on the sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball val...

Page 12: ...re that all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metal...

Page 13: ...should illuminate without any alarms Wait 5 minutes for UV lamp to reach full power Slowly turn the feed valve counterclockwise until fully open the handle should be in line with the tubing as it ent...

Page 14: ...L Replace every 12 months Quartz Sleev Model QS 212 Replace as needed during lamp change Part Image 8851 2J03 B423 Booster Pump TACS 114 48 Pump Power Supply PSW240 Shut Off Switch LPS340G Low Pressur...

Page 15: ...tions All pre and post filters should be replaced every 3 6 months Before starting shut off cold water supply to unit and unplug the UV system Lift the handle on the faucet to drain out the storage ta...

Page 16: ...V lamp in upward direction from the UV chamber and lamp connector base Hold the UV lamp at the ceramic ends Insert the new UV lamp fully into the UV chamber leaving about two inches of the UV lamp pro...

Page 17: ...with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be completely cleaned or it is scratched or cracked then replace the sleeve Reinstall the qu...

Page 18: ...oap Pour about teaspoon of Hydrogen Peroxide or household bleach into each filter housing and replace housings on the RO system Open the feed water valve and open the RO faucet until water flows freel...

Page 19: ...ed in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that your incoming water is below 77 F It may be necessary to change to a higher flow membra...

Page 20: ...his system contains a UV Lamp Do not operate the UV Lamp when it is removed from the chamber Unintended use or damage of the system may result in the exposure of dangerous UV radiation UV radiation ma...

Page 21: ...min If these parameters are not being met please check the following Is the system receiving adequate feed water The pump s inlet chamber must be flooded to prevent performance robbing air ingestion...

Page 22: ...____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________________...

Page 23: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Page 24: ...ent Prefilter Stage 1 2 H F2510AC Carbon Block Pre filters Stages 2 3 1 H F1032 43A Carbon Post Filter Stage 5 with QC adapters RFK 5 PRE Pre Filter Pack Membrane Sold Separately Includes 1 H F1005CF...

Reviews: