background image

Installation and Service Manual – Under-the-Counter Point of Use 6 Stage Reverse Osmosis System with Pump & UV 

 

Copyright © 2020 WaterAnywhere. 

All Rights Reserved.

 

Page 10 

 

 

Step 4 – System Feed Line Installation 

For this step you will need: 

 ½” 

and 

7

/

16

” open-end wrenches (or two adjustable wrenches) 

 Teflon 

Tape 

  Feed Adapter & Ball Valve Kit 

 Tubing 

Locate and Turn Off the Cold Water Supply 

  Locate the valve in the cold water feed line you use for the supply.   

 Notice:

 

Accidentally hooking up the system to the hot water supply line will permanently 
damage the membrane (see conditions for operation).  To assure you are using the 
cold water line, turn on both the hot and cold faucet.  After the water is warm to the 
touch, feel the pipes under the sink.  It will be easy to identify the hot and cold pipes. 

 

  Close the cold water valve.   

  Turn on the sink faucet to drain water and relieve pressure from the lines.   

  If no shut off valve is located under the sink, or if water continues to come out of the faucet, turn off the 

main supply at the entry to the house, then turn on the sink faucet to drain water and relieve pressure from 
the lines. 

Assemble the Ball Valve & Adapter Kit 

  Use Teflon tape to wrap the threads of the ball valve – approximately 3 wraps.

 

 

  Screw the ball valve into the adapter.   

 

Install the Feed Adapter into the Cold Water Supply 

 

  Wrap the slip joint adapter with Teflon tape, approximately 3 wraps. 

 

For Flex Line:   

Loosen nut and separate cold water riser tube from faucet 

shank.  Gently bend riser rube so that slip joint fits onto faucet shank.   Make 
sure the flat washer is on top and the cone washer is on the bottom.   
Reinstall riser tubes onto slip joint adapter and tighten.   
 

 

For Solid Copper Riser Tube

: Same procedure as flex tubing except you 

must cut a piece of the riser tube about ¾” to 1” so the slip joint adapter can 
fit between faucet and riser tube. 
 

Connect the Feed Line Tubing  

  Unscrew the nut from the ball valve.  Slide the nut onto the tubing, threaded sides facing the end of the 

tubing.  Feed the nipple on the ball valve into the 
tubing, pushing the tubing until it slides over the lip.  
Slide the nut to the threads on the ball valve, and 
tighten the nut down over the tubing.   Use a wrench to 
tighten ¼ turn past finger-tight. 

  Connect the other end of the tubing to the feed port on 

the RO System. 

Summary of Contents for AAA-RO50PUVW

Page 1: ...om 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 6 Stage Point of Use RO UV Drinking Water System with Pump Document ID AAAROPUVW Revision 05 13 20 AAA RO50...

Page 2: ...he RO membrane the heart of the RO system substantially reduces the total dissolved solids TDS from the water including arsenic barium cadmium chromium hexavalent chromium trivalent copper turbidity f...

Page 3: ...ifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step 3 Drain Saddle Installation 9 Step 4 Syste...

Page 4: ...e of a water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologic...

Page 5: ...ng D Housing with the RO Membrane E Tank Shut Off Valve F Four way Valve G In Line Cartridge with Activated Carbon H Flow Restrictor I Tank Valve J Tank K UV System L Faucet 1 Clean Water Outlet 2 Pol...

Page 6: ...pplies UV Controller should be mounted to the wall see System Mounting section Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system...

Page 7: ...ings and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cau...

Page 8: ...t surface at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires...

Page 9: ...p or sink top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by...

Page 10: ...e Starting with the drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not dril...

Page 11: ...on the sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball val...

Page 12: ...re that all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metal...

Page 13: ...should illuminate without any alarms Wait 5 minutes for UV lamp to reach full power Slowly turn the feed valve counterclockwise until fully open the handle should be in line with the tubing as it ent...

Page 14: ...L Replace every 12 months Quartz Sleev Model QS 212 Replace as needed during lamp change Part Image 8851 2J03 B423 Booster Pump TACS 114 48 Pump Power Supply PSW240 Shut Off Switch LPS340G Low Pressur...

Page 15: ...tions All pre and post filters should be replaced every 3 6 months Before starting shut off cold water supply to unit and unplug the UV system Lift the handle on the faucet to drain out the storage ta...

Page 16: ...V lamp in upward direction from the UV chamber and lamp connector base Hold the UV lamp at the ceramic ends Insert the new UV lamp fully into the UV chamber leaving about two inches of the UV lamp pro...

Page 17: ...with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be completely cleaned or it is scratched or cracked then replace the sleeve Reinstall the qu...

Page 18: ...oap Pour about teaspoon of Hydrogen Peroxide or household bleach into each filter housing and replace housings on the RO system Open the feed water valve and open the RO faucet until water flows freel...

Page 19: ...ed in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that your incoming water is below 77 F It may be necessary to change to a higher flow membra...

Page 20: ...his system contains a UV Lamp Do not operate the UV Lamp when it is removed from the chamber Unintended use or damage of the system may result in the exposure of dangerous UV radiation UV radiation ma...

Page 21: ...min If these parameters are not being met please check the following Is the system receiving adequate feed water The pump s inlet chamber must be flooded to prevent performance robbing air ingestion...

Page 22: ...____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________________...

Page 23: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Page 24: ...ent Prefilter Stage 1 2 H F2510AC Carbon Block Pre filters Stages 2 3 1 H F1032 43A Carbon Post Filter Stage 5 with QC adapters RFK 5 PRE Pre Filter Pack Membrane Sold Separately Includes 1 H F1005CF...

Reviews: