background image

-2-

6.  If  there  are  union  couplings  in 

the piping, loosen all three union 

couplings close to the tank using 

the  pipe  wrench  and  adjustable 

wrench.  Undo  completely  when 

they are loose enough to work by 

hand.  The  pipes  will  come  apart 

when the couplings disconnect.

7.  Loosen  and  remove  all  the  bolts 

that  anchor  the  pump  to  the 

pump  stand  using  the  adjustable 

wrench.  Remove  the  pump  from 

the  pump  stand  of  the  existing 

tank. 

(Fig. 4) 

If there is not enough 

slack in the wiring to let the pump 

rest  on  the  floor,  either  rest  it 

on  a  stool  or  the  new  pump,  or 

disconnect the wiring. Don’t let it 

hang in the air.

8.  Remove the plastic cap on the air 

valve  on  top  of  the  tank.  Check 

the  air  charge  in  the  new  tank 

using the tire pressure gauge.

 

Adjust  the  pre-charge  pressure 

in  the  tank  to  be  1-2  psi  below 

the  pressure  switch  pump  cut-in 

setting. First look inside the cap to 

the pressure switch to determine 

the pump cut-in setting. It should 

say  “20/40”  or  “30/50”  or  the 

like.  The  pressure  in  the  tank 

should  be  adjusted  to  be  2  psi 

below  the  lower  pressure  of 

these  two  numbers.  That  is,  the 

tank  pressure  should  be  set  at 

about 18 psi if the cap indicates a 

setting of 20/40, or set at about 

28 if the cap indicates a setting 

of 30/50.

 

If this charge is too high, release 

some  air  by  pressing  down  on 

the pin inside the air valve. If the 

charge  is  too  low,  pump  it  up 

using  a  bicycle  tire  pump  or  air 

compressor.

 

Alternatively,  you  can  adjust 

the  pressure  switch  to  match 

the  pressure  in  the  tank.  See 

instructions on the inside of the 

pressure  switch  cap  for  how  to 

do this.

9.  Place  the  pump  on  the  pump 

stand  of  the  new  tank. 

(Fig.  5) 

Do not insert the bolts yet. (You 

will  need  to  move  the  pump 

around to pipe it to the existing 

pipes.)

10. Install the new tank.

a.  Remove  the  inlet  pipe  to  the 

existing  tank. 

(Fig.  6) 

Either 

re-use the existing inlet assembly, 

or purchase a tank installation kit, 

which should include: a 3/4” x 4” 

or so pipe nipple; a 3/4” fpt x 3/4” 

fpt x 3/4” fpt pipe tee; and a 3/4” 

fpt  standard  drain/boiler  drain 

valve.

b.  Apply  Teflon

®

  tape  to  the 

threaded  male  end  of  this  inlet 

pipe which inserts into the tank.

c.  Insert  this  inlet  pipe  into  the 

female pipe threaded opening at 

the end of the new tank. Tighten 

hand  tight.  Then  wrench  tight 

using  the  pipe  wrench  and  the 

12”  adjustable  wrench. 

(Fig.  7-8) 

Make  sure  that  the  pipe  to  the 

supply  line  ends  up  in  a  vertical 

position  pointing  up.  Tighten 

slowly  to  make  sure  you  do  not 

over  tighten. 

(Fig.  8) 

Do  not 

loosen the pipe once tightened. If 

you do, it is more likely to leak.

d.  Move the existing tank out of the 

way. Discard.

e.  Move  the  new  tank  into  position 

with the inlet assembly attached.

f.  If the two tanks are the same size, 

then the piping will match up.

 

If the two tanks are different sizes, 

then  the  piping  for  the  new  tank 

probably will not match the old. In 

this  case,  adjust  the  piping  to  fit. 

If  pipes  are  mismatched  by  only 

a small amount, you can force the 

pipes to fit or use nipples that are 

longer  or  shorter  to  make  ends 

meet.

g.  Match  up  the  union  couplings. 

Tighten  hand  tight. 

(Fig.  9) 

Tighten until wrench tight to seal, 

using  the  12”  adjustable  wrench 

and the pipe wrench. 

(Fig. 10)

h.  Insert the bolts for the pump into 

place to hold it to the stand. Move 

the tank as necessary underneath 

the  pump  to  make  the  holes  in 

the  pump  line  up  with  the  holes 

in  the  pump  stand.  Screw  on  the 

nuts to the bolts. Tighten wrench 

tight using the adjustable wrench.  

(Fig. 11)

11.  Examine  the  plumbing  system  to 

see  if  you  have  a  pressure  relief 

valve  between  the  pump  and  the 

tank. 

Always be sure 

to  equip  your 

well system with a proper Pressure 

Relief Valve.

 

The  system  shows  what  the 

Pressure  Relief  Valve  should  look 

like. 

(Fig. 12)

 

If  you  do  have  a  Pressure  Relief 

Valve  in  the  system,  go  on  to  

Step 12. 

 

If you do not:

a.  Remove the boiler drain from the 

inlet valve now on the tank. Make 

the  pipe  tee/nipple  assembly. 

Wrap  Teflon

®

  tape  around  one 

of  the  male  threaded  ends  of 

the  nipple.  Insert  it  in  one  of  the 

female  threaded  openings  in  the 

3/4”  fpt  x  3/4”  fpt  x  3/4”  fpt 

pipe tee. Tighten hand tight, then 

wrench tight. 

b.  Install  the  pipe  tee  /  nipple 

assembly. 

(Fig.  13) 

Apply  Teflon

®

 

tape  to  the  male  thread  at  the 

other  end  of  the  nipple  (which  is 

now half inside the pipe tee). Insert 

the  pipe  tee  /  nipple  assembly 

in  the  female  threaded  opening 

on  the  tank  inlet  assembly  from 

which  you  removed  the  boiler 

drain.  Tighten  hand  tight,  then 

wrench tight.

drip 

pan 

connected  to 

an  adequate  drain  must  be 

installed  if  leaking  and  flooding 

could  cause  property  damage  to 

the area adjacent to the appliance 

or to lower floors of the structure.

c.  Install  the  pressure  relief  valve. 

Apply  Teflon®  tape  to  the  male 

threaded end of the valve.

 

Insert  the  pressure  relief  valve  in 

the  female  threaded  opening  on 

the  side  of  the  pipe  tee.  Tighten 

hand  tight,  then  wrench  tight. 

(Fig. 14)

d.  Insert  the  standard  drain  in  the 

female threaded opening of the end 

of  the  pipe  pee/nipple/pressure 

relief valve assembly. Tighten hand 

tight, then wrench tight. 

(Fig. 15)

12.  Open the ball or gate valve on the 

pump feed line. 

(Fig. 16)

 Open the 

ball  or  gate  valve  on  the  supply 

line.

4

10

11

12

13

14

15

5

6

7

8

9

Summary of Contents for HT14HB

Page 1: ...MES WITH A 5 YEAR WARRANTY SEE WATER WORKER LIMITED WARRANTY FOR DETAILS READ CAREFULLY THE PRODUCT INSTALLATION OPERATING AND MAINTENANCE MANUAL FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE...

Page 2: ...osen the pipe once tightened If you do it is more likely to leak d Move the existing tank out of the way Discard e Move the new tank into position with the inlet assembly attached f If the two tanks a...

Page 3: ...alfunctioning or shows signs of corrosion call a qualified professional immediately Current copies of the Product manual can be viewed at www waterworkerdiy com Use proper safety equipment when instal...

Page 4: ...a WATER WORKER authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty this Warranty also does not cover repair or repla...

Page 5: ...t me pour puits Ce produit est fourni avec une garantie de 5 ans Voir la garantie limit e de WATER WORKER pour les d tails VEUILLEZ LIRE ATTENTIVEMENT LE MANUEL D INSTALLATION DE FONCTIONNEMENT ET D E...

Page 6: ...l extr mit du nouveau r servoir Serrez manuellement Puis bien serrer avec la cl tuyau et la cl ajustable de 30 48 cm 12 po Fig 7 8 Assurez vous que le tuyau la conduite d alimentation soit en positio...

Page 7: ...faillance pr matur e Remarque inspectez l appareil pour des dommages encourus lors de l exp dition Si vous constatez des dommages avisez imm diatement le transporteur ou le magasin o l achat a t effe...

Page 8: ...KER un distributeur ou un d taillant autoris WATER WORKER plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie La pr sente garantie ne couvre pas les co ts d...

Page 9: ...5 a os Consultar la Garant a Limitada de WATER WORKER para mas detalles LEA DETENIDAMENTE EL MANUAL DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO DEL PRODUCTO SI NO SIGUE LAS INSTRUCCIONES Y LAS ADVER...

Page 10: ...sici n vertical apuntando hacia arriba Ajuste lentamente para asegurarse de no ajustar de m s Fig 8 No afloje la tuber a una vez ajustada Si lo hace es m s probable que haya filtraciones d Quite el ta...

Page 11: ...materiales si el producto parece funcionar mal o muestra signos de corrosi n llame a un profesional calificado de inmediato Las copias actualizadas del Manual del producto se pueden encontrar en www w...

Page 12: ...un minorista o un distribuidor autorizado de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu Esta garant a tampoco cubre los costos de reparaci n ni...

Reviews: