WS1HR & WS1.25HR Manual
Page 9
Injector Cap, Screen, Injector Plug and Injector
The screen, injector and/or injector plug(s) are installed under the injector cap in an easy to access location on top of the valve. The
injector cap contains four slots so no water accumulates in the cap. The injector cap is designed to be hand tightened.
Under the injector cap there is an easy to clean removable screen to prevent fouling of the injector. There are two holes under the
injector cap labeled “DN” and “UP”. The holes will be fi lled with a plug or an injector.
The plug (Order # V3010-1Z) prevents water from traveling a certain pathway. The injector lets water pass through the pathway.
The self-priming injector increases the velocity of the water, creating a zone of negative pressure that draws in the concentrated
liquid regenerant, such as sodium chloride (brine), potassium permanganate, etc. The regenerant blends with the stream of water,
which passes through the media to regenerate the bed.
The injector provides a consistent regenerant/water mixture ratio over the entire operating pressure range of the control valve. The
injector provides good performance in a variety of applications, which may involve elevated drain lines and long regenerant draw
lengths. Injectors are chosen by knowing the type, amount, and regenerant fl ow rate for a particular type of media. Guidelines can
be found in the media manufacturer’s literature. The color coded injectors give different regenerant draw, slow rinse and total fl ow
rates over the pressure range. See Table 6 for color codings, and injector graphs for total, slow rinse and draw fl ow rates.
The control valve has been manufactured to be one of the following:
•
regeneration downfl ow WS1HR & WS1.25HR (for softeners or regenerating fi lters install injector in DN location, plug in UP
location)
•
regeneration upfl ow WS1HR only (upfl ow option is for softeners only, install injector in UP location, plug in other hole
location)
•
no regenerant WS1HR & WS1.25HR (both the DN and UP holes have injector plugs installed) and plug installed for the refi ll
elbow
NOTE: It is not recommended to fi eld convert valves from upfl ow to downfl ow and vice versa. Separate areas in the valve supply
water to the injector for upfl ow and downfl ow valves.
Refi ll Flow Control Assembly or Refi ll Port Plug
The refi ll fl ow control assembly consists of a refi ll fl ow elbow, refi ll fl ow control retainer assembly, refi ll fl ow control, polytube
insert and nut assembly. The refi ll fl ow control retainer fi ts in the refi ll elbow. The refi ll fl ow control retainer houses the refi ll fl ow
control which controls the fl ow rate when the regenerant tank is being refi lled. The refi ll fl ow control is a fl exible washer-like
part with a small orifi ce and a precision molded contour that delivers a steady 0.5 gpm regenerant tank refi ll rate at varying inlet
pressures. Refi ll is accomplished with treated water.
4
Actual tank size used may vary depending on the design and application of the system. Tank diameter is an approximation for the following:
1. downfl ow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride.
2. upfl ow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride, an inlet water pressure
of 30 to 50 psi and water temperature of 60°F water or warmer. Higher pressures or lower temperatures would need smaller injectors to avoid
lifting the bed.
Table 6
Injector Order Information
Typical Tank Diameter
4
Injector Order Number
Injector Color
Down
WS1HR & WS1.25HR
Up
WS1HR Only
V3010-1A
Black
6"
8"
V3010-1B
Brown
7"
9"
V3010-1C
Violet
8"
10"
V3010-1D
Red
9"
12"
V3010-1E
White
10"
13"
V3010-1F
Blue
12"
14"
V3010-1G
Yellow
13"
16"
V3010-1H
Green
14"
18"
V3010-1I
Orange
16"
22"
V3010-1J
Light Blue
18"
V3010-1K
Light Green
22"
Summary of Contents for WS1HR
Page 2: ......
Page 13: ...WS1HR WS1 25HR Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 30: ...Page 30 WS1HR WS1 25HR Manual Drawings and Part Numbers...
Page 42: ...Page 42 WS1HR WS1 25HR Manual Flow Diagrams Service and Backwash...
Page 43: ...WS1HR WS1 25HR Manual Page 43 Flow Diagrams Downflow and Upflow WS1HR Only...
Page 44: ...Page 44 WS1HR WS1 25HR Manual Flow Diagrams Rinse and Fill...
Page 54: ...Page 54 WS1HR WS1 25HR Manual...
Page 55: ...WS1HR WS1 25HR Manual Page 55...
Page 56: ...Page 56 WS1HR WS1 25HR Manual...
Page 57: ...WS1HR WS1 25HR Manual Page 57...
Page 58: ...Page 58 WS1HR WS1 25HR Manual...
Page 59: ...WS1HR WS1 25HR Manual Page 59...