8
PROGRAMMING PROCEDURES
1. Set time of day:
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
STEP 1
– Press
CLOCK
.
STEP 2
–
CURRENT TIME (HOUR):
Set the hour of the day using
+
or
—
buttons. AM/PM toggles after 12. Press
NEXT
to go to step 3.
STEP 3
–
CURRENT TIME (MINUTES):
Set the minutes using
+
or
—
buttons. If it is desired to back up to the previous
step press
REGEN
button once.
STEP 4
–
CURRENT DAY:
Set the day of the week using
+
or
—
buttons. Pressing
NEXT
will exit
SET
CLOCK
and return to
the general operating display.
1
TIME
HOUR
AM
SET
2:00
TIME
MINUTES
AM
SET
2:00
2
3
CURRENT DAY
SET
MON
4
Return to general display.
NOTE:
The manufacturer has preset the unit so that the gallons between regenerations will be
automatically calculated after the hardness is entered. Press
NEXT
to cycle to the next step or
REGEN
to return to the previous step.
STEP 1
– Press
NEXT
and
+
simultaneously for 3 seconds.
STEP 2
–
HARDNESS:
Set the amount of hardness in grains per gallon (default 20) using the
+
or
—
buttons. The allowable range is from 1 to 150 in 1 grain increments.
NOTE:
If a resin media is used in the softener, increase the grains per gallon if
soluble iron is present (1 ppm = 4 gpg). This display will show “GALLONS AVAILABLE
BETWEEN REGENERATIONS” if “FILTER” is selected.
STEP 3
–
DAY OVERRIDE:
The manufacturer has factory set 12 DAYS as the default. This
is the maximum number of days between regenerations. If this is set to “OFF”,
regeneration initiation is based solely on gallons used. If any number is set (allowable
range from 1 to 28), a regeneration initiation will be called for on that day even if a
sufficient number of gallons were not used to call for a regeneration.
Set Day Override using
+
or
—
buttons (12 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF”.
STEP 4
–
REGENERATION HOUR:
The manufacturer has factory set 2:00 A.M. as the default.
This is the hour of day for regeneration and can be reset by using
+
or
—
buttons.
“AM/PM” toggles after 12. The default time is 2:00 a.m. (recommended for a normal
household).
STEP 5
–
REGENERATION MINUTES:
Set the minutes using
+
or
—
buttons.
STEP 6
–
BACKLIGHT DISPLAY CONTROL
(Not available on all models)
:
Set the display
backlight on or off using
+
or
—
buttons. In the OFF position, the backlight will turn
off after 5 minutes of inactivity.
1
DAYS BETWEEN REGEN
SET
12
3
WATER HARDNESS
SET
20
2
REGEN TIME HOUR
AM
GR
SET
2:00
4
REGEN TIME MINUTES
AM
SET
2:00
5
Return to general display.
LIGHT NORMALLY
SET
ON
6
Optional
Display