background image

22

Water 

Flow

6

9

Drain 

Line 

1”

4

1

3

5

7

8

2

Proper DLFC orientation

directs water flow towards

the washer face with

rounded edge.

DRAIN LINE ASSEMBLY 1”

Item No.

Part No.

Description

Qty.

1

CH4615

 Elbow locking clip

1

2

CV3166

 Drain FTG body 1

1

CV3166-01

 FTG flow control body 1

3

CV3167

 Drain FTG adapter 1

1

4

CV3163

 O-ring 019

1

5

CV3150

 Split ring

1

6

CV3151

 Nut 1" QC

1

7

CV3105

 O-ring 215

8

CV3190-090

 9.0 gpm DLFC for 1” elbow

One DLFC 

must be 

used if 1" 

fitting is 

used

CV3190-100

 10.0 gpm DLFC for 1” elbow

CV3190-110

 11.0 gpm DLFC for 1” elbow

CV3190-130

 13.0 gpm DLFC for 1” elbow

CV3190-150

 15.0 gpm DLFC for 1” elbow

CV3190-170

 17.0 gpm DLFC for 1” elbow

CV3190-200

 20.0 gpm DLFC for 1” elbow

CV3190-250

 25.0 gpm DLFC for 1” elbow

9

CV3008-04

 FTG Drain 1" Strt No/Sil

1

REPLACEMENT PARTS

Water flow 

Proper DLFC orientation

directs water flow towards

the washer face with

rounded edge.

DRAIN LINE ASSEMBLY 3/4”

Item No.

Part No.

Description

Qty.

1

CH4615

 Elbow locking clip

1

2

CPKP10TS8-BULK  

Optional 

insert, 5/8” tube

1

3

CV3192

 

Optional 

nut, 3/4” drain elbow

1

4

CV3158-02

 Drain elbow, 3/4” NPT with O-ring

1

5

CV3163

 O-ring 019

1

6

CV3159-01

 DLFC retainer assembly

1

7

CV3162-007

 0.7 DLFC for 3/4” elbow

1

CV3162-010

 1.0 DLFC for 3/4” elbow

CV3162-013

 1.3 DLFC for 3/4” elbow

CV3162-017

 1.7 DLFC for 3/4” elbow

CV3162-022

 2.2 DLFC for 3/4” elbow

CV3162-027

 2.7 DLFC for 3/4” elbow

CV3162-032

 3.2 DLFC for 3/4” elbow

CV3162-042

 4.2 DLFC for 3/4” elbow

CV3162-053

 5.3 DLFC for 3/4” elbow

CV3162-065

 6.5 DLFC for3/4” elbow

CV3162-075

 7.5 DLFC for 3/4” elbow

8

CV3331

 Drain elbow and retainer assembly

    

Items 2 and 3, nut and insert are only used with 

1/2” I.D. by 5/8” O.D. polytubing. For other piping 

material, the 3/4” NPT is used.

Summary of Contents for IMP-844

Page 1: ...Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 935 IMPC 1035...

Page 2: ...erstand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer or Water Right at the...

Page 3: ...Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing NEXT to scroll through them When stepping through any programming if no but...

Page 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...nd the water conditioner should be as short as possible see step 8 2 Since salt must be added periodically to the brine tank it should be in an easily accessible location 3 It is NOT recommended to in...

Page 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Page 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Page 8: ...increments NOTE If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show GALLONS AVAILABLE BETWEEN REGENERATIONS if FILTER...

Page 9: ...the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly media will be lost to the drain 3 When the water is f...

Page 10: ...ed or when the system has been operated without salt To initiate a manual regeneration at the next preset regeneration time press and release REGEN The words REGEN TODAY will flash on the display to i...

Page 11: ...operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERROR appears and flashes alternately with...

Page 12: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Page 13: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Page 14: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Page 15: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Page 16: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Page 17: ...17 This page left intentionally blank...

Page 18: ...lack Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3579WI PC board Impression 1 CV3813WP PC board Impressio...

Page 19: ...nerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ri...

Page 20: ...PARTS 2 4 1 3 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Altho...

Page 21: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Page 22: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Page 23: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Page 24: ...AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWS HEH Top Assembly Light Gray Dark Gray 1 2 CJ2B35E Bottom Assembly Light Gray with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with...

Page 25: ...25 This page left intentionally blank...

Page 26: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Page 27: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Page 28: ...MODEL IMPC SPECIFICATIONS MODEL IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Rated Softener Capacity Grains Lbs Salt Minimum 13 700 3 4 18 200 4 5 18 200 4 5 27 600 7 0 36 400 9 0 45 800 11 5 M...

Page 29: ...replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes an...

Page 30: ...stored in memory no matter how long the power outage 1 Accessed by pressing SET CLOCK 2 Adjust hours with and buttons AM PM toggles at 12 3 Press NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6...

Page 31: ...31 This page left intentionally blank...

Page 32: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right Inc All rights reserved MAN IMP CERT RevA0818...

Reviews: