8.913-970.0 - L • WATERMAZE CLP 5024/7034
OPERA
T
OR’S MANU
AL
W
A
TER TREA
TMENT
SYSTEM
26
OZONE SPECIFICATIONS
NOTE:
There are two fi laments - an upper and a lower -
inside the lamp. Place one of the voltmeter leads on one
of the lamp prongs and, with the other lead, touch all of
the three remaining prongs. If continuity is not achieved
on both upper and lower fi laments, replace the ozone
lamp (Part #6-0534)
To test the power pack, use a voltmeter set on the cor-
rect voltage (120V or 240V). Place one of the voltmeter
leads into the lamp plug where the white wire goes into
it and plug the other voltmeter lead into the lamp plug
where the blue wire goes into it. If no voltage is present
replace the ozone ballast (Part #6-05231 - 120V, Part
#6-05232 - 240V). When ordering an ozone ballast, you
also need the 4-pin connector (Part #6-05233).
Replacing the lamp:
(
See Ozone Generator Breakdown
)
Lamp replacements are available from your
WATER
MAZE
Dealer should they need to be replaced. Simply
turn off the power to the CLP at the breaker, remove the
screws on the power pack cover and remove the cover.
Disconnect the plug on the end of the ozone lamp. Now,
loosen the lamp holder locking ring from around the end
of the lamp by turning it counterclockwise and remove
it. Remove the lamp by grabbing the rubber bushing
around the end of the lamp and pulling it straight out.
Remove the rubber bushing from the lamp and install
it on your new lamp, making sure the outer edge of the
bushing is fl ush with the outer edge of the silver end cap
on the lamp. Now, slide the lamp back into the reaction
chamber. The lamp holder may now be reinstalled and
tightened. Reinstall the plug onto the lamp and replace
the power pack cover.
CAUTION: Keep the lamp free of fi ngerprints and
dust particles by only handling the metal end caps
on the lamp. You can clean the lamp with rubbing
alcohol and a soft cloth. A dirty lamp will not allow
maximum ozone output.
SPECIFICATIONS
Energy required 110V:
105VAC MIN., 125VAC MAX., .800 AMP/Ballast
Energy required 220V:
210VAC MIN., 230V MAX., .450AMP/Ballast
Power Consumption:
20 Watts
Average Lamp Life:
9,000 Hours
Lamp Wave length:
185 nm
in hazardous radiation exposure, and may be considered
an act of modifying or new manufacturing of a laser
product under U.S. regulations contained in 21CFR
Chapter 1, subchapter J.
CAUTION: Avoid exposure to direct or strongly
refl ected germicidal ultraviolet rays.
DO NOT STARE INTO BEAM.
ATTENTION: Éviter l'exposition aux rayons ultra-
violets germicides fortement réfl échis.
NE PAS REGARDER DIRECTEMENT LE FAISCEAU.
DANGER: Ultraviolet radiation. Disconnect
Power Before Replacing Lamp.
ATTENTION: Radiation ultraviolette. Débrancher
l'alimentation avant de remplacer la lampe.
DANGER: Connect only to a circuit that is protect-
ed by Ground Fault Circuit Interrupt (GFCI).
DANGER: Raccorder uniquement à un circuit qui
est protégé par un disjoncteur différentiel de fuite
à la terre (DDFT).
Testing the Lamp:
(
See Ozone Generator Testing Illus.)
To test the ozone lamp, use a voltmeter set on ohms.
First remove the ozone cover and unplug the lamp plug
from the ozone lamp.
89139700-34
Four Pin
Connector
Ozone
Lamp
Prongs
Ballast
OZONE GENERATOR TESTING