9
User Displays
General Operation
When the system is operating one of two displays will be shown. Pressing UP or DOWN button will
alternate between the displays. One of the displays is always the current time of day (to the nearest hour).
The second display is the days remaining until next regeneration. If the days’ remaining is equal to one, a
regeneration will occur at the next preset regeneration time. The user can scroll between displays as
desired.
If the system has called for a regeneration that will occur at the present time of regeneration, the arrow will
point to Regen.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water
usage is when a household is asleep. If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change to indicate the cycle of the regeneration
process (see Table 3) that is occurring and an arrow will also point to Regen. The system will run through
the steps automatically and will reset itself provide treated water when the regeneration is completed.
Manual Regeneration
Sometimes there is need to regenerate the system, sooner than when the system calls for it, usually
referred to as a manual regeneration. There may be a period of heavy water usage because of guests or
a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, simultaneously press UP-
DOWN buttons together and release. The arrow will point to the word Regen if a regeneration is expected
"tonight". To cancel the regeneration simultaneously press UP + DOWN buttons and release.
To initiate a manual regeneration immediately, simultaneously press UP + DOWN buttons together for
three seconds. The system will begin to regenerate immediately. The request cannot be cancelled. Note:
For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before
regenerating.
Set Time of Day
STEP 1U
– Press SET HOUR
STEP 2U
– Current: Set the clock to the closest hour by using the UP and DOWN button. An arrow points
to PM after 12. After a power outage, the time of day will need to be reset. Press SET HOUR to exit.
Power Loss
If the power goes out current timer of day will need to be reset. If the power goes out while the system is
regenerating, the cycle picks up where it was interrupted when the power returns. Note: The display will
flash if a power outage has occurred.
Error Message
If "E1," "E2" or "E3" appears on the display contact the help.
This indicates that the valve did not function properly.