User Displays 

 

General Operation 

 
When the system is operating one of two displays will be shown. Pressing UP or DOWN button will 
alternate between the displays. One of the displays is always the current time of day (to the nearest hour). 
The second display is the days remaining until next regeneration. If the days’ remaining is equal to one, a 
regeneration will occur at the next preset regeneration time. The user can scroll between displays as 
desired. 
 
If the system has called for a regeneration that will occur at the present time of regeneration, the arrow will 
point to Regen. 
 
Regeneration Mode 
 
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water 
usage is when a household is asleep. If there is a demand for water when the system is regenerating, 
untreated water will be used. 
 
When the system begins to regenerate, the display will change to indicate the cycle of the regeneration 
process (see Table 3) that is occurring and an arrow will also point to Regen. The system will run through 
the steps automatically and will reset itself provide treated water when the regeneration is completed. 
 

Manual Regeneration 

 
Sometimes there is need to regenerate the system, sooner than when the system calls for it, usually 
referred to  as a manual regeneration. There may be a period of heavy water usage because of guests or 
a heavy laundry day. 
 
To initiate a manual regeneration at the preset delayed regeneration time, simultaneously press UP-
DOWN buttons together and release. The arrow will point to the word Regen if a regeneration is expected 
"tonight". To cancel the regeneration simultaneously press UP + DOWN buttons and release. 
 
To initiate a manual regeneration immediately, simultaneously press UP + DOWN buttons together for 
three seconds. The system will begin to regenerate immediately. The request cannot be cancelled. Note: 
For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before 
regenerating. 
 

Set Time of Day 

 

STEP 1U

 – Press SET HOUR 

 

STEP 2U 

– Current: Set the clock to the closest hour by using the UP and DOWN button. An arrow points 

to PM after 12.  After a power outage, the time of day will need to be reset. Press SET HOUR to exit. 
 

Power Loss 

 
If the power goes out current timer of day will need to be reset. If the power goes out while the system is 
regenerating, the cycle picks up where it was interrupted when the power returns. Note: The display will 
flash if a power outage has occurred. 
 

Error Message 

 
If "E1," "E2" or "E3" appears on the display contact the help. 
This indicates that the valve did not function properly. 

 

Summary of Contents for Blaster Soft

Page 1: ...Blaster Soft System Owner s Manual CANADIAN ADDRESS 92 Commerce Park Dr Unit 2 Barrie ON L4N 8W8 Canada www waterdepot com...

Page 2: ...the performance of the Blaster then you should call for service Your dealer is trained in testing water and setting your machines according to the recommendation of the manufacturer Failure to provid...

Page 3: ...Drawings and Part Numbers 17 Front Cover and Drive Assembly 18 Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston and Spacer Stack Assembly 19 Drive Cap Assembly Downflow Piston Regera...

Page 4: ...y should flash all wording then flash the software version e g 154 and then reset the valve to the service position All plumbing should be done in accordance with local plumbing codes The pipe size fo...

Page 5: ...s leaking tightening the nut will not stop the leak Remove the nut remove the fitting and check for damage or misalignment of the o ring Do not use pipe dope or other sealant on threads Teflon tape mu...

Page 6: ...6...

Page 7: ...s to PM the right Access the mode by pressing during p m hours Simultaneously press SET HOUR and UP simultaneously for SET HOUR and DOWN to return to 3 seconds normal operation The user can initiate m...

Page 8: ...28 minutes DAY OVERRIDE IS SET FOR 3 DAYS Reminder The unit must go off every 3rd day if you want to remove Sulphur and Iron etc You can custom change anything you want but make sure the relay does n...

Page 9: ...e the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a man...

Page 10: ...4 to 6 minutes 6 Press NEXT Should flash Brine Down Set for 30 up to 60 minutes 7 Press NEXT Should flash Capacity unit size usually set for 30 000 grains 8 Press NEXT Should flash Auto press plus or...

Page 11: ...11...

Page 12: ...12...

Page 13: ...13 Example Brine Line Installation...

Page 14: ...rounding clips and remove from generator 4 Run warm water through the inlet tubing until the water from the outlet tubing runs clear and free or particulates 5 Use compressed air to completely dry the...

Page 15: ...15...

Page 16: ...16 Platinum Drawings and Part Numbers...

Page 17: ...V 12V EU CLK V3186UK WD1 AC ADAPTER 220 240V 12V UK CLK V318601 WD1 AC ADAPTER CORD ONLY Relay Specifications To insure proper fit and correct operation the following relay and relay socket manufactur...

Page 18: ...Downflow ASY 1 4b CLK V301101 WD1 Piston Upflow ASY 5 CLK V3174 WD1 Regenerant Piston 1 6 CLK V3135 O ring 228 1 7 CLK V3180 O ring 337 1 8 CLK V3105 O ring 215 Distributor Tube 1 Not Shown CLK V3001...

Page 19: ...O ring 228 1 7 CLK V3180 O ring 337 1 8 CLK V3358 O ring 219 Distributor Tube Opening 1 32 1 CLK V3357 O ring 218 Distributor Tube Opening 32mm Not Shown CLK V3020 WD1 25 Body ASY Downflow Distributo...

Page 20: ...01F WD1 INJECTOR ASY F BLUE CLK V30101G WD1 INJECTOR ASY G YELLOW CLK V30101H WD1 INJECTOR ASY H GREEN CLK V30101I WD1 INJECTOR ASY I ORANGE CLK V30101J WD1 INJECTOR ASY J LIGHT BLUE CLK V30101K WD1 I...

Page 21: ...This part is required for backwash only systems 2 CLK H4615 Elbow Locking Clip 1 3 CLK JCPP6 Polytube insert 3 8 1 4 CLK JCPG6PBLK Nut 3 8 1 5 CLK H4613 Elbow Cap 3 8 1 6 CLK V3163 O ring 019 1 7 CLK...

Page 22: ...for CLK V3162013 WD1 DLFC 1 3 gpm for CLK V3162017 WD1 DLFC 1 7 gpm for CLK V3162022 WD1 DLFC 2 2 gpm for CLK V3162027 WD1 DLFC 2 7 gpm for CLK V3162032 WD1 DLFC 3 2 gpm for CLK V3162042 WD1 DLFC 4 2...

Page 23: ...ion Quantity 1 CLK V3151 WD1 Nut 1 QC 1 2 CLK V3003 WD1 Meter ASY 1 3 CLK V311801 WD1 Turbine ASY 1 4 CLK V3105 O ring 215 1 5 CLK V300301 WD1 Meter Plug ASY 1 6 CLK V3013 Mixing Valve Optional Order...

Page 24: ...g 215 2 3 CLK V3105 O Ring 215 2 4 CLK V3149 WD1 Fitting 1 PVC Male NPT Elbow 2 4 CLK V3189 WD1 Fitting 1 PVC Solvent 90 2 Order No CLK V300702 Description WD1 Fitting 1 Brass Sweat Assembly Order No...

Page 25: ...2 3 CLK V3105 O Ring 215 2 4 CLK V3164 WD1 Fitting 1 Plastic Male NPT 2 4 CLK V3317 WD1 Fitting 1 Plastic Male NPT 2 Order No CLK V300704 Description WD1 Fitting 1 Plastic Male NPT Assembly Order No...

Page 26: ...pass Cap 2 6 CLK V3147 WD1 Bypass Handle 2 7 CLK V3148 WD1 Bypass Rotor Seal Retainer 2 8 CLK V3152 O ring 135 2 9 CLK V3155 O ring 112 2 10 CLK V3156 O ring 214 2 Not Shown Order No CLK V319101 Descr...

Page 27: ...319301 Although no tools are necessary to assemble or disassemble the valve the WS1 wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Econo Air Birm Ins...

Page 28: ...Listen to back wash 1 Check for obstruction in backwash Check flow restrictor Regenerate more often 2 Check the ozone generator is working 3 Clean the ozone tube Overview Most service should be aroun...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32...

Reviews: