Water Care Ion Pro Series Installation Instructions & Owner'S Manual Download Page 12

12

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY 

and 

TIME OF DAY 

will flash alternately if a regeneration 
is expected tonight.

4.  

MANUAL REGENERATION:

 

Sometimes there is a need to regenerate before the control 

valve calls for it. This may be needed if a period of heavy water use is anticipated.

 • 

 

To initiate a manual regeneration 

at the next preset regeneration time,

 

press and release 

REGEN

. The words “REGEN TODAY” will flash on the 

display to indicate that the system will regenerate at the next regeneration 
time (set in Programming, steps 4 and 5). 

If you pressed the 

REGEN

 button 

in error, pressing the button again will cancel the command.

 • 

 

To initiate a manual regeneration 

immediately,

 press and hold the 

REGEN

 

button for three seconds. The system will begin to regenerate immediately. 

This command cannot be cancelled.

      Once a manual regeneration is initiated, the unit will enter the first regeneration 

cycle. Once the unit advances to its first position and subsequent positions 
thereafter (see Start Up Instructions for regeneration sequence), the water filter 
will deliver water, but it will be untreated. 

5.   

POWER LOSS AND BATTERY REPLACEMENT:

 The transformer comes 

with a 15 foot power cord and is designed for use with the control valve; the 
transformer should only be used in a dry location. 

      In the event of a power outage, the control valve will remember all settings and time of 

day. If an extended power outage occurs, the control valve will keep time of day until 
the battery is depleted. When the battery becomes depleted, the only item that needs 
to be reset is the time of day and will be indicated by the time of day flashing or by a 
blank screen. All other settings are permanently stored in the nonvolatile memory.

      If a power loss occurs and the time of day flashes or a blank screen occurs, this 

indicates that the battery is depleted. The time of day should be reset and the non-
rechargeable battery should be replaced. The battery is a 3 Volt Lithium Coin Cell 
type 2032 and is readily available at most stores. To access battery location, remove 
front cover (

see diagram on page 18 for battery location).

 

6.   

AUDIBLE ALARM:

 

This control valve is equipped with an audible alarm and 

visual alarm. This alarm is set by the installing dealer and is used to warn of 
pending service, based on gallons or time. 

     

  To turn off alarm: 

If the audible alarm sounds, press any button on the 

face of the control valve to turn off and call the dealer for service.

     

  To reset: 

Both the gallon alarm setting and time alarm setting are reset 

together by pushing and holding the + and – simultaneously for three seconds.

7.   

ERROR MESSAGE:

 

If the word “ERROR” appears and flashes alternately with the 

dealer name and phone number, record the ERROR number and your contact servicing 
dealer promptly. This indicates that the control valve was not able to function properly.

8.  

 CHLORINE TANK AND MAINTENANCE: 

In severe cases where iron or sulfate bacteria conditions exist, the dealer 

may have installed a chlorine tank with your system 

(see diagram, page 7)

. These bacteria are harmless to human 

health, however they can produce a slime and occasionally an odor that can be a nuisance. Filters equipped with a 
chlorine tank will periodically draw a chlorinated water solution into the filter tank killing these unwanted bacteria within 
the filter itself. The chlorine is rinsed from the system during the regeneration process. More specifically, a small amount of 
water will be added to the tank just prior to regeneration; this comes in contact with the chlorine pellets, dissolves them, 
and is drawn into the filter to disinfect the system periodically. 

      We recommend the use of pellets manufactured by Better Water Industries, available through your dealer. Periodically 

check storage tank and add two or three chlorine tablets (two or three grams) at a time. 

CAUTION:

  

This tank has many intended uses. If chlorine is being used, only add two or 
three pellets (two or three grams) of chlorine at a time. We recommend Better 
Water Industries chlorine pellets. Do not overfill container. Use rubber gloves 
when handling pellets. Always read safety precautions of chemical container 
before adding to tank. Keep out of reach of children!

  

     If chlorine is being used, never add or mix any chemical in chlorine tank other 

than chlorine. Only use in well ventilated area. Chlorine gas can be corrosive and 
harmful. Inhalation of chlorine gas can be deadly. Use drip pan underneath tank 
in case of corrosion or leaking of tank.

MANUAL REGENERATION 

BATTERY REPLACEMENT

ERROR

Summary of Contents for Ion Pro Series

Page 1: ...Ion Pro and CareClear Pro Series Water Filters For Models IPHS IPFE IPG IPCG AN CCP CCP AN...

Page 2: ...ty 30 Quick Reference Guide 31 32 Your WaterCare water filters are precision built high quality products These units will deliver filtered water for many years to come when installed and operated prop...

Page 3: ...y Remaining and Days to a Regeneration are optional displays but are not normally used Vacation Mode is used only when there will be no water usage for an extended period of time If activated once 50...

Page 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Page 5: ...een its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on the outlet side of the...

Page 6: ...low control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but because of...

Page 7: ...regeneration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use...

Page 8: ...neration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 3 is recommended set number of days...

Page 9: ...t OFF as the default This feature is used to signal service into the future This is typically set by the installing dealer to warn homeowner that service is required after a preset number of gallons h...

Page 10: ...ushing and holding the REGEN button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The sys...

Page 11: ...system goes through a regeneration cycle based on the days override value 6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed this screen will only appear if set by...

Page 12: ...ed with an audible alarm and visual alarm This alarm is set by the installing dealer and is used to warn of pending service based on gallons or time To turn off alarm If the audible alarm sounds press...

Page 13: ...o media level when filling Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the right height has been...

Page 14: ...board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed...

Page 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Page 16: ...r 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap...

Page 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Page 18: ...iston position or disconnect power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detec...

Page 19: ...buttons 1 CV3837 01 CareClear Pro cover blue buttons 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV4062WX PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV30...

Page 20: ...w 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 CV3358 O ring 219 1 25 distributor 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 003183...

Page 21: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...

Page 22: ...0 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN not shown CV3170 O ring 011 lower not shown CV317...

Page 23: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Page 24: ...1 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the...

Page 25: ...LY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH4640 32 474 float assembly 1 3 CH4500 48 474 air check 1 4 CN1043 10 pad for feeder 1 5 CH7001 Grid for feeder 1 REPLACEMENT...

Page 26: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Page 27: ...Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assem...

Page 28: ...19 0 22 0 Continuous Flow GPM 3 0 3 0 5 0 3 0 3 0 5 0 2 Peak Flow GPM 6 0 8 0 10 0 6 0 8 0 10 0 Backwash Flow GPM 6 5 9 0 11 0 6 5 9 0 11 0 3 Iron Removal 4 0 4 0 4 0 4 0 4 0 4 0 4 Hydrogen Sulfide Re...

Page 29: ...1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 5 0 5 0 6 0 6 0 7 0 11 0 Peak Flo...

Page 30: ...xpense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition...

Page 31: ...N TIME MINUTES SET TIME HOUR SET 2 00 AM MANUAL REGENERATION NOTE For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regeneration If you need to initia...

Page 32: ...d button simultaneously 2 Adjust hardness using and buttons 3 Press NEXT 4 Adjust days between regenerations using and buttons 5 Press NEXT 6 Adjust time of regeneration hour with and buttons AM PM to...

Reviews: