background image

Power Requirements

The Direct DC Terminal Adapter is shipped with the Firebox. If you prefer to use an AC
adapter, you must order it separately from your WatchGuard reseller. You can find a
reseller on the

WatchGuard Find Resellers

page.

The Direct DC Terminal Adapter connects your T35-R directly to your power supply. The DC power
requirements are:

n

Input: 12 - 48VDC +/-5% at 50/60Hz

n

Maximum Power Consumption: 24W DC, for example:

o

12VDC at 2A

o

48VDC at 0.5A

Environmental Requirements

To safely install your Firebox, we recommend that you:

n

Turn off electrical power to the circuit until the adapter and earth ground are connected, and you are
ready to turn on the Firebox.

n

Put it in a secure area, such as a locked room, to block the device from people who do not have
permission to use it.

n

Connect it to a conditioned power supply to prevent damage from sudden power changes.

Other environmental requirements:

n

Operating temperature: -40° to 60°C (-40° to 140°F)

n

Operating humidity: 5% to 90% non-condensing

n

Non-operating temperature: –40° to 70°C (-40° to 158°F)

n

Non-operating humidity: 5% to 90% non-condensing

Hardware Description

Front

Front view of the Firebox:

WatchGuard Firebox T35-R Hardware Guide

2

WatchGuard Technologies, Inc.

Summary of Contents for Firebox T35-R

Page 1: ...Firebox T35 R Hardware Guide Firebox T35 R DS3AE5...

Page 2: ...y providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission i...

Page 3: ...Hardware Specifications 1 Interface Specifications 1 Power Requirements 2 Environmental Requirements 2 Hardware Description 2 Front 2 Rear 4 Direct DC Terminal Adapter 4 Connect Firebox Cables 5 DIN R...

Page 4: ...hardware product Firebox T35 R is a rugged version of the Firebox T35 suitable for installation in harsh environments outside a typical small office or rack room Fireware OS The Firebox T35 R support...

Page 5: ...ox we recommend that you n Turn off electrical power to the circuit until the adapter and earth ground are connected and you are ready to turn on the Firebox n Put it in a secure area such as a locked...

Page 6: ...e status of the external network connection If the device can connect to the external network and send traffic the indicator is green The indicator flashes if the device cannot send traffic to the ext...

Page 7: ...y If you prefer to use an AC adapter you must order it separately See the installation instructions in Direct DC Terminal Adapter Ground Terminal The ground terminal indicated by is where you connect...

Page 8: ...the Firebox Connect Firebox Cables Connect the Ethernet cables to complete the setup with WatchGuard System Manager or the Fireware Web UI 1 Use an Ethernet cable to connect interface 1 of the Firebo...

Page 9: ...WatchGuard Firebox T35 R Hardware Guide 6 WatchGuard Technologies Inc Restore Factory Default Settings If you have a problem in your configuration file that you cannot correct you can restore the fact...

Reviews: