WATANABE WPMZ-5 Quick Instruction Manual Download Page 7

 

 

MODEL WPMZ-5-□□□-□□-□□□                                                                                 

 

7/12 

 

                                                                                                                                                                                                 

IM-0834-03 

9. 

 

SETTING EXAMPLES

 

The instantaneous followings are some examples for some 
necessary setting point and operation methods to perform flow 
measurements. 

 

9-1. 

 

SETTING EXAMPLE 1 

Detecting pulses from a gear wheel which generates 5 pulses 

per  1  round  by  proximity  switch  (open  collector  output)  and 

displays the revolving speed in [rpm]. 

 

Input type setting 

The  sensor  is  an  open  collector  type,  therefore  “open 

collector” should be selected as the input type. 

 

Setting for revolving speed

 display

 

For  setting  of 

Instantaneous  display  coefficient,  Number  of 

rotation per 1 pulse is needed. 

Calculate the n

umber of rotation per 1 pulse. 

  Because of 5 [Pulse] per 1 round, therefore, 

1/5

2×10

-1

[round] 

Set  ”  2.00000×10

-1

”  as  the  Instantaneous  display 

coefficient   

Unit  to  display  is  [rpm],therefore,  select  “Min”  for  the 

instantaneous unit time. 

By “instantaneous decimal point position”, set the number 

of digits after the decimal point. 

 

Setup steps   

Although  setup  steps  are  basically  same  as  “8.BASIC 

OPERATION  OF  SETTING  DISPLAY”,  setting  of 

instantaneous  display  factor  is  needed,  an  example  is 

shown below. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9-2. 

 

Setting Example 2 

Using a gearbox of 805[rpm] with an open collector output, 

displaying  the  circumferential  speed  of  the  roll  diameter 

350[mm] in [m/min] 

conditions

 

rotation speed 805[rpm]

 

 

output pulse 60[P/R] built-in

 

reduction ratio

 

1/90 

roll diameter 350[mm] 

 

Input type setting 
The  sensor  is  an  open  collector  type,  therefore  “open 
collector” should be selected as the input type. 

 

Setting for circumferential speed display 

For setting of 

Instantaneous display coefficient, travel distance of 

rotation per 1 pulse is needed.

 

calculation of circumferential speed 

805[rpm] ×1/90× (0.35[m]×3.14)=9.82994[m/min] 

  Cumulate 

travel distance per 1 pulse

 

1/60[P/R]×1/90×

0.35[m]×3.14

)=

2.03518×10

-4

[m/Pulse] 

Set “2.03518×10

-4

” as the Instantaneous display coefficient 

Display  is  in  [min],therefore,  “Min”  is  selected  for  the 

instantaneous unit time. 

By “instantaneous decimal point position”, set the number 

of digits after the decimal point. 

 

9-3. 

 

SETTING EXAMPLE 3 

When maximum flow rate is approx. 40[ℓ/min], using a sensor of 
rating  7.5[mℓ/Pulse]  (open  collector  type),  instantaneous  flow 
rate will be displayed in [ℓ/min]. 

 

Input type setting 

The sensor is an open collector output type, therefore select 

“open collector” as input type. 

 

Setting for instantaneous flow rate display 

Set flowrate per 1 pulse as instantaneous display 

coefficient   

Although  instantaneous  flow  rate  will  be  displayed  in 

[ℓ/min], the rating of the sensor is 7.5[mℓ/Pulse], it should 

be converted to 7.5×10

-3

[ℓ/Pulse]. 

Set the “Instantaneous display factor” as “7.50000×10

-3

” 

Displayed unit is [ℓ/min], therefore select “Minute” as the 

instantaneous unit time. 

By “instantaneous decimal point position”, set the number 

of digits after the decimal point 

 

9-4. 

 

SETTING EXAMPLE 4 

Using a sensor (Voltage output type) which outputs 15 [Hz] for 

90[ℓ/min], instantaneous flow rate will be displayed in [ℓ/sec]. 

 

Input type setting 

The sensor is Voltage output type, therefore select “LOGIC” 

for “input type”. 

 

Setting for instantaneous flow rate display 

Set flowrate per 1 pulse as “instantaneous display 

coefficient”. 

Calculate number of pulses per 1 [ℓ]. 

The sensor outputs pulses of 15[Hz] at 90[ℓ/min], therefore, 

15×60

/90

10[Pulse/ℓ] . 

Calculate flowrate per 1 pulse. 

Number of pulses per 1 litter is 10[Pulse/ℓ], therefore, 

1/10

1×10

-1

[ℓ/Pulse]. 

Set  “1.00000×10

-1

”  for  the  “instantaneous  value  display 

coefficient”.   

*  Any  settings  of  “1.00000×10

-1

”,  “0.10000×10

0

”  and 

“0.01000×10

1

”  for  the  “instantaneous  value  display 

coefficient” bring same results. 

Unit  to  display  is  [ℓ/sec],  therefore,  select  “Sec”  for  the 

“instantaneous unit time”. 

By “instantaneous decimal point position”, set the number 

of digits after the decimal point. 

 

10. 

 

SETTING OF UNITS 

Units are selectable and can be displayed optionally. 

 

If units should be used is not available, custom units up to   

 

6 characters are can be made. 

  *

For custom units, please refer to the detailed manual which can be 

 

 

downloaded from our home page. 

 

10-1. 

 

LOCATIONS OF PARAMETERS FOR UNIT SETTING 

1st layer 

2nd layer 

3rd layer 

1.input 

setting 

pulse input A 

pulse input B

 

Instantaneous display 

unit 

2 input 

calculation 

Instantaneous display 

unit 

MENU

(Measurement display)

1st layer

2nd layer

3rd layer

Moves to setting display(1st layer)by 

MENU key.

Moves to 2nd 

layer by right 

arrow key.

Moves to 

instantaneous 

display coefficient 

by down arrow key.

Moves to 3rd layer 

by right arrow key.

3rd layer

4th layer

Moves to 

numerical value 

setting display 

by ENTER key.

Moves to 4th layer 

by right arrow key.

ENTER

4th layer(numerical value setting)

Registers selected 

numerical value by 

ENTER key.

Selects numerical value by arrow 

keys (up/down/left/right)

4th layer

3rd layer

Returns to 3rd 

layer by left 

arrow key.

ENTER

MENU

Returns to 2nd layer 

by left arrow key.

Moves to other setting 

items by up/down 

arrow keys.

Stores selected parameters 

and returns measurement 

display by MENU key.

4th layer(numerical value setting)

Summary of Contents for WPMZ-5

Page 1: ...Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same duct with lines including noises might cause malfunctions 4 The WPMZ becomes available functionally right after power activation but requires 30 minutes warming to satisfy all performance requirements Note The inputs A channel and B channel may be ...

Page 2: ...NE Ach Line driver input terminal 16 GND Ach GND input terminal 17 EXC Ach sensor power output terminal 18 EXC Ach sensor power output terminal 19 20 NC No connection Non usable for a relay terminal B channel line driver input terminal name description 21 LINE Bch Line driver input terminal 22 LINE Bch Line driver input terminal 23 GND Bch GND input terminal 24 EXC Bch sensor power output terminal...

Page 3: ...tive Indicates comparative output reset function an external control function is effective Indicates measurement inhibit function an external control function is effective Indicates display hold function an external control function is effective Indicates maximum value or minimum value hold function an external control function is effective 5 2 2 Key Operation Icons On The Setting Display Key oper...

Page 4: ...imes 8times 9times Set number of moving average Instantaneous value simple average InsSimpleAve None None 2 times 4 times 8 times 16 times 32 times 64 times 128 times 256 times Set number of simple average for internal sampling 10ms Instantaneous value display step InsDispStep None None 5steps 10steps Setting of steps of display If set to 5steps displayed only 0 or 5 on LSB WPMZ 5 L Pulse Input A ...

Page 5: ...0bps 19200bps 38400bps Set baudrate Data length DataLength 8bit 7bit 8bit Set data character length Parity Parity None None Even Odd Set parity bit Stop bit Stopbit 1bit 1bit 2bit Set stop bit length Delimiter Delimiter CR CR CR LF Set delimiter type 3 Display Display Select Measure select MeasureSelect 1input InsA 2inputs InsA InsB InsA InsB InsCalc InsA InsB InsCalc A B InsA Comp InsB Comp InsCa...

Page 6: ...ting items If the arrow key LEFT is pushed the display returns to the 2nd layer On the 3rd layer by pushing the MENU key the display returns to the measurement display By moving the cursor with arrow key UP DOWN select a setting item If the arrow key LEFT is pushed the display returns to the 2nd layer At the selected setting item by pushing arrow key RIGHT the display moves to the 4th layer settin...

Page 7: ...r 1 pulse as instantaneous display coefficient Although instantaneous flow rate will be displayed in ℓ min the rating of the sensor is 7 5 mℓ Pulse it should be converted to 7 5 10 3 ℓ Pulse Set the Instantaneous display factor as 7 50000 10 3 Displayed unit is ℓ min therefore select Minute as the instantaneous unit time By instantaneous decimal point position set the number of digits after the de...

Page 8: ...common for AL1 AL4 in open collector output products Each AL1 2 AL3 4 have common terminal in relay ouput products 11 3 COMPARISON JUDGEMENT VALUE The comparison judgement value is a threshold value to judge Although the setting procedure is same as 8 BASIC OPERATIONS FOR SETTING DISPLAY comparison judgement values need the settings of numerical values Therefore its procedure is shown below The fo...

Page 9: ...d Bch 12 7 PATTERN SELECT FUNCTION The pattern select function is the function which switches the pattern number to use for measurement By using pattern select 1 3 Up to 8 patterns can be switched Function Name Selected pattern No pattern No in use 1 2 3 4 5 6 7 8 Pattern select1 Open Short Open Short Open Short Open Short Pattern select2 Open Open Short Short Open Open Short Short Pattern select3...

Page 10: ...ys Please refer to 14 1 Locations of parameters for initialize 14 3 2 Initializing To User Defaults By executing to initialize to user defaults current setting values are replaced by user defaults Steps for the initialize operation are same as 14 2 Initializing to the factory defaults Operate the WPMZ according to the setting displays Please refer to 14 1 Locations of parameters for initialize 15 ...

Page 11: ... structure IP66 front Installation environment indoor use Rated altitude up to 2000m Transient overvoltage Ⅱ Measurement category Ⅱ Pollution degree 2 Conformed EN standard EN61326 1 EMS industrial electromagnetic environment EMI Class A Applicable to line length only under 30m EN61010 1 EN50581 Material of enclosure polycarbonate PC black UL94V 0 Input Specifications Pulse input instantaneous mea...

Page 12: ...ay value AL2 zone upper limit or AL2 zone lower limit display value AL2 display value AL3 zone upper limit or AL3 zone lower limit display value AL3 display value AL4 zone upper limit or AL4 zone lower limit display value AL4 Conversion method D A conversion method Resolution capability Equivalent of 13bit Scaling Digital scaling Output objective Response speed Specification for each output An ite...

Reviews: