WATANABE WPMZ-5 Quick Instruction Manual Download Page 4

 

 

 

MODEL WPMZ-5-□□□-□□-□□□

 

                                                                                                         

4/12

 

 

                                                                                                                                                                                                 

IM-0834-03 

BASIC OPERATIONS, SETTINGS                                                                                                                                                                       

6. 

 

BASIC OPERATIONS OF MEASUREMENT DISPLAY 

During measurement mode, the following key operations can be done.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
  

 

By pushing the “DISP key” in the measurement mode, the display can be switched to others which are selected in “display select”. 

 

By pushing the “MENU key” in the measurement mode, the display moves to the setting display. 

Alternatively, by pushing the “MENU key” in the setting display, the display returns to the measurement display 

 

By pushing the “FUNC key” in the measurement mode, the display moves to the shortcut entry display. 

Alternatively, by pushing the “FUNC key” in the shortcut entry display, the display returns to the measurement display. 

 

During measurement, by holding down the “arrow key” in 1 second, the shortcut function registered to the key will be executed. 

On this occasion, the display has no change. 

 

7. 

 

SETTING LAYER OVERVIEW 

       

The setting menus of the WPMZ which are represented by key words and have layers, therefore desired setting menu can be selected   

       

accurately. The layers consist of 1st layer to 4th layer (Only custom unit setting has the 5th layer). 

Please refer to “

8. BASIC OPERATION OF SETTING DISPLAY

” about how to set up. 

 
 

1st layer 

Large categories 

2nd layer 

Small    categories 

3rd layer (setting items) 

4th layer    (setting contents) 

Remarks 

name of item 

Character strings on 

display 

(abbreviated form) 

Initial values 

Settable variables 

1.Input 

(WPMZ-5-

P

 
 
 
 
 
 
 
 

Pulse input A 
 
Pulse input B 
 
 
 
 
 
 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 

 

Input type 

InputType 

OpenCollector 

OpenCollector/Logic/ZeroCross/2Wire 

Select input signal type 

Input filter 

InputFilter 

None 

None/30Hz/1.5kHz/15kHz 

Select analog input filters 

Sensor power 

SensorPower 

12V 

12V/24V 

Switch Sensor power voltage 

Instantaneous value 
display coefficient 

InsDispCoef 

1.00000×10

0

 

0.00000 to 9.99999×10

-9

9

 

For scaling setting of instantaneous value display, 
multiply frequency by instantaneous coefficient and 
unit time. 
 

Instantaneous unit 
time 

InsUnitTime 

Sec 

Sec/Min/Hour 

Instantaneous value 
decimal point position 

InsDecPoint 

###### 
  (No decimal point) 

######/  #####.#/  ####.##/  ###.###/  ##.####/ 
#.##### 

Set number of digits after decimal point 

Instantaneous value 
display unit 

InsDispUnit 

None 

None/select from 62 units (See 6-2)/custom unit 

Refer to detailed instruction manual about custom 
unit 

Instantaneous value 
auto zero 

InsAutoZero 

0.00 

0.00 to 99.99sec 

Displays 0 if no pulse input over more than setting 
time 

Instantaneous value 
moving average 

InsMoveAve 

None 

None/2times/3times  /4times  /5times  /6times 
/7times /8times / 9times 

Set number of moving average. 

Instantaneous 
value simple average 

InsSimpleAve 

None 

None/2 times /4 times /8 times /16 times /32 times 
/64 times /128 times /256 times 

Set number of simple average for internal sampling 
(10ms) 

Instantaneous value 
display step 

InsDispStep 

None 

None/5steps/10steps 

Setting of steps of display 

If set to 5steps, displayed 

only 0 or 5 on LSB

 

(WPMZ-5-

L

 
 
 
 
 
 
 
Pulse Input A 
 
Pulse Input B 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 

 

Input Type 

InputType 

Line driver 

Line driver 

Only line driver 

Input filter 

InputFilter 

None 

None 

None analog filters 

Sensor Power 

SensorPower 

5V 

5V 

Sensor power is 5V only 

Instantaneous value 
display Coefficient 

InsDispCoef 

1.00000×10

0

 

0.00000 to 9.99999×10

-9

9

 

For scaling setting of instantaneous value display, 
multiply frequency by instantaneous coefficient and 
unit time. 

 

Instantaneous value 
unit time 

InsUnitTime

 

Sec 

Sec/Min/Hour 

Instantaneous value 
decimal point position 

InsDecPoint 

###### 
(No decimal point) 

######/ #####

#/ ####

##/ ###

###/   

##

####/ #.##### 

Set number of digits after decimal point 

Instantaneous value 
display unit 

InsDispUnit 

None 

None/select from 62 units (See 6-2)/custom unit 

Refer  to  detailed  instruction  manual  about  custom 
unit 

Instantaneous value 
auto zero 

InsAutoZero

 

0.00 

0.00 to 99.99 sec 

Displays 0 if no pulse input over more than setting 
time

 

Instantaneous value 
moving average 

InsMoveAve 

None 

None/2times/3times  /4times  /5times  /6times 
/7times /8times / 9times 

Set number of moving average for analog inputs 

Instantaneous 
value simple average 

InsSimpleAve 

None 

None/2 times /4 times /8 times /16 times /32 times 
/64 times /128 times /256 times 

Set number of simple average 

Instantaneous value 
display step 

InsDispStep 

None 

None/5steps/10steps 

Setting of steps of display 

If set to 5steps, displayed 

only 0 or 5 on LSB

 

2 input 
calculation 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 
 

Expression for 
instantaneous value 

InsExpression 

None 

None/ (B/A)*100 / (B/A-1)*100 /B-A / 
(B/(A+B))*100 / A+B 

Select  expression  for  calculation  of  instantaneous 
value. 

Instantaneous value 
decimal point position 

InsDecPoint 

###### 
  (No decimal point) 

######/  #####.#/  ####.##/  ###.###/  ##.####/ 
#.##### 

Set number of digits after decimal point 

Instantaneous value 
display unit 

InsDispUnit 

None 

None/select from 62 units (See 6-2)/custom unit 

Refer to detailed instruction manual about custom 
unit 

Instantaneous value 
display step 

InsDispStep 

None 

None/5steps/10steps 

Setting of steps of display 

If set to 5steps, displayed 

only 0 or 5 on LSB

 

MENU

DISP

DISP

DISP

FUNC

  Execute a shortcut function

*The function is valid, only if the 
shortcut function is assigned to 
the arrow key.

(Hold down 2 sec.)

or

or

or

DISP

MENU

FUNC

Summary of Contents for WPMZ-5

Page 1: ...Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same duct with lines including noises might cause malfunctions 4 The WPMZ becomes available functionally right after power activation but requires 30 minutes warming to satisfy all performance requirements Note The inputs A channel and B channel may be ...

Page 2: ...NE Ach Line driver input terminal 16 GND Ach GND input terminal 17 EXC Ach sensor power output terminal 18 EXC Ach sensor power output terminal 19 20 NC No connection Non usable for a relay terminal B channel line driver input terminal name description 21 LINE Bch Line driver input terminal 22 LINE Bch Line driver input terminal 23 GND Bch GND input terminal 24 EXC Bch sensor power output terminal...

Page 3: ...tive Indicates comparative output reset function an external control function is effective Indicates measurement inhibit function an external control function is effective Indicates display hold function an external control function is effective Indicates maximum value or minimum value hold function an external control function is effective 5 2 2 Key Operation Icons On The Setting Display Key oper...

Page 4: ...imes 8times 9times Set number of moving average Instantaneous value simple average InsSimpleAve None None 2 times 4 times 8 times 16 times 32 times 64 times 128 times 256 times Set number of simple average for internal sampling 10ms Instantaneous value display step InsDispStep None None 5steps 10steps Setting of steps of display If set to 5steps displayed only 0 or 5 on LSB WPMZ 5 L Pulse Input A ...

Page 5: ...0bps 19200bps 38400bps Set baudrate Data length DataLength 8bit 7bit 8bit Set data character length Parity Parity None None Even Odd Set parity bit Stop bit Stopbit 1bit 1bit 2bit Set stop bit length Delimiter Delimiter CR CR CR LF Set delimiter type 3 Display Display Select Measure select MeasureSelect 1input InsA 2inputs InsA InsB InsA InsB InsCalc InsA InsB InsCalc A B InsA Comp InsB Comp InsCa...

Page 6: ...ting items If the arrow key LEFT is pushed the display returns to the 2nd layer On the 3rd layer by pushing the MENU key the display returns to the measurement display By moving the cursor with arrow key UP DOWN select a setting item If the arrow key LEFT is pushed the display returns to the 2nd layer At the selected setting item by pushing arrow key RIGHT the display moves to the 4th layer settin...

Page 7: ...r 1 pulse as instantaneous display coefficient Although instantaneous flow rate will be displayed in ℓ min the rating of the sensor is 7 5 mℓ Pulse it should be converted to 7 5 10 3 ℓ Pulse Set the Instantaneous display factor as 7 50000 10 3 Displayed unit is ℓ min therefore select Minute as the instantaneous unit time By instantaneous decimal point position set the number of digits after the de...

Page 8: ...common for AL1 AL4 in open collector output products Each AL1 2 AL3 4 have common terminal in relay ouput products 11 3 COMPARISON JUDGEMENT VALUE The comparison judgement value is a threshold value to judge Although the setting procedure is same as 8 BASIC OPERATIONS FOR SETTING DISPLAY comparison judgement values need the settings of numerical values Therefore its procedure is shown below The fo...

Page 9: ...d Bch 12 7 PATTERN SELECT FUNCTION The pattern select function is the function which switches the pattern number to use for measurement By using pattern select 1 3 Up to 8 patterns can be switched Function Name Selected pattern No pattern No in use 1 2 3 4 5 6 7 8 Pattern select1 Open Short Open Short Open Short Open Short Pattern select2 Open Open Short Short Open Open Short Short Pattern select3...

Page 10: ...ys Please refer to 14 1 Locations of parameters for initialize 14 3 2 Initializing To User Defaults By executing to initialize to user defaults current setting values are replaced by user defaults Steps for the initialize operation are same as 14 2 Initializing to the factory defaults Operate the WPMZ according to the setting displays Please refer to 14 1 Locations of parameters for initialize 15 ...

Page 11: ... structure IP66 front Installation environment indoor use Rated altitude up to 2000m Transient overvoltage Ⅱ Measurement category Ⅱ Pollution degree 2 Conformed EN standard EN61326 1 EMS industrial electromagnetic environment EMI Class A Applicable to line length only under 30m EN61010 1 EN50581 Material of enclosure polycarbonate PC black UL94V 0 Input Specifications Pulse input instantaneous mea...

Page 12: ...ay value AL2 zone upper limit or AL2 zone lower limit display value AL2 display value AL3 zone upper limit or AL3 zone lower limit display value AL3 display value AL4 zone upper limit or AL4 zone lower limit display value AL4 Conversion method D A conversion method Resolution capability Equivalent of 13bit Scaling Digital scaling Output objective Response speed Specification for each output An ite...

Reviews: