WATANABE WPMZ-5 Quick Instruction Manual Download Page 5

 

 

MODEL WPMZ-5-□□□-□□-□□□                                                                                 

 

5/12 

 

                                                                                                                                                                                                 

IM-0834-03 

 

2nd layer 

Small    categories 

3rd layer (setting items) 

4th layer    (setting contents)

 

Remarks

 

name of item 

Character strings on 

display 

(abbreviated form) 

Initial    values 

Settable variables 

1.Input 

External 
Control 

Function of external 
control terminal 1 to 5 

ExtCtrl1Func 

ExtCtrl2Func 

ExtCtrl3Func 

ExtCtrl4Func 

ExtCtrl5Func 

None 

None/ CompareReset/ MeasureBlockA/ 
MeasureBlockB/ MeasureBlockA&B/ 
DispHoldA&B/ DispHoldA/ DispHoldB/

 

 

MaxHoldA/ MaxHoldB/ MaxHoldA&B/ MinHoldA/ 
MinHoldB/ MinHoldA&B/PatternChange1/ 
PatternChange2/ PatternChange3/ 
MonitorChange/ TrendHold 

Select functions assigned to external control 
terminals. 

2.Output 

Comparative 
Output AL1 
 
Comparative 
Output AL2 
 
Comparative 
Output AL3   
 
Comparative 
Output AL4   
 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 

 

Source output display 
value 

OutputDispValue 

None 

None/InsA/InsB/InsCalc 

Select source output display value to compare. 

Compare mode 

CompareMode 

LevelJudge 

LevelJudge/ ZoneJudge 

Select compare mode 

Condition of ON 

OnConditions 

Excess 

Excess/LessThan   

In level judge mode 

InTheZone 

InTheZone/OutsideTheZone 

In Zone judge mode 

Comparison 
judgement value 

Threshold 

10000 

Threshold

±999999 

Hysteresis

0 to 999999 

In level judge mode 

10000 

Zone lower limit

±999999 

Zone upper limit 

±999999 

Hysteresis

0 to 999999 

In Zone judge mode 

Comparison ON delay 

OnDelay 

None 

None/20ms/50ms/100ms/200ms/500ms 
1s/5s/10s/20s 

Comparative  output  turns  ON,  if  ON  condition 
continues over set delay time. 

Comparison OFF 
delay 

OffDelay 

None 

Comparative  output  turns  OFF,  if  OFF  condition 
continues over set delay time. 

Output mode 

OutputMode 

Normal 

Normal/Latch/OneShot5ms/ OneShot 10ms/ 

OneShot 20ms/OneShot 50ms/ OneShot 0.1s/ 

OneShot 0.2s/ OneShot 0.5s/ OneShot 1s/   

OneShot 2s 

Select output mode of comparison 

Output logic 

OutputLogic 

Negative(NO) 

Positive(NC)/Negative(NO) 

NC/NO are for relay output product. 

Background  Color  at 
ON 

OnBgColors 

Black 

Black/Red/Yellow/Green 

Background color priority 
AL1>AL2>AL3>AL4 

Analog Output 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 
 

Output range 

OutputRange 

0-10V 

0-10V/±10V/1-5V/0-20mA/4-20mA 

Select output range (type). 

Source  output  display 
value 

OutputDispValue 

None 

None/InsA/InsB/InsCalc 

Select    a displayable item for analog output 

Output scale 

OutputScale 


10000 

0% display value 

±999999 

100% display value 

±999999 

Set scaling for analog output. 
Set expected display values at 0% and 100% output. 

BCD Output 

Pattern select 

PatternSelect 

Pattern1(or  pattern  No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 

Source  output  display 

value 

OutputDispValue 

None 

None/InsA/InsB/InsCalc 

Select a displayable item for BCD output 

Data signal logic 

DataSignalLogic 

Negative 

Positive /Negative 

Select logic of data signal output. 

Synchronous signal 

logic 

SyncSignalLogic 

Negative 

Positive /Negative 

Select logic of synchronous signal (PC) output. 

RS-485   
Modbus 
communication 

SlaveAddress 

SlaveAddress 

1/2/3/4/ 

・・・・・

  /30/31 

Set ID number. 

Baudrate 

Baudrate 

19200bps 

9600bps/19200bps/38400bps 

Set baud rate. 

Parity 

Parity 

Even 

None/Even/Odd 

Set parity bit. 

RS-232C 

commu
nication 

Protocol 

Protocol 

Modbus-RTU 

Modbus-RTU/OriginalCommand/OriginalOutput 

Set protocol 

Baud rate 

Baudrate 

19200bps 

9600bps/19200bps/38400bps 

Set baudrate. 

Data length 

DataLength 

8bit 

7bit/8bit 

Set data character length 

Parity 

Parity 

None 

None/Even/Odd 

Set parity bit. 

Stop bit 

Stopbit 

1bit 

1bit/2bit 

Set stop bit length. 

Delimiter 

Delimiter 

CR 

CR/CR LF 

Set delimiter type. 

3.Display 

Display Select 

Measure select 

MeasureSelect 

1input: 

InsA 

2inputs

 

InsA+ InsB 

InsA/InsB/InsCalc/ InsA+InsB / A+B/ 
InsA+Comp/InsB+Comp/Comp 

Select displayable items can be switched by DISP 
key or external control (multiple selects are 
available) 

Level select 

LevelSelect 

InsA/InsB/InsCalc/ InsA+InsB   

Select an item displayed on level display 

Trend select 

TrendSelect 

Select an item displayed on trend display. 

Level Display 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 

 

Instantaneous value A 
scale 

InsA Scale 


10000 

Lower limit

±999999 

Upper limit

±999999 

Set display scale of level display. 
Left edge of display is lower limit and right edge of 
display is higher limit   

Instantaneous value B 
scale 

InsB Scalse 

Instantaneous 
calculation scale 

InsCalcScale 

Trend Display 

Pattern select 

PatternSelect 

Pattern1(or pattern No. 
in use) 

Pattern1/ Pattern 2/ Pattern 3/ Pattern 4/ Pattern 
5/ Pattern 6/ Pattern 7/ Pattern 8 

Select pattern No. to set. 
 

Instantaneous value A 
scale 

InsA Scale 


10000 

Lower limit 

±999999 

Upper limit 

±999999 

Set display scale of trend display. 
Bottom edge of display is lower limit and top edge of 
display is higher limit. 

Instantaneous value B 
scale 

InsB Scale 

Instantaneous 
calculation scale 

InsCalcScale 

Time axis 

TimeAxis 

1s/div 

1s/div,2s/div,5s/div,10s/div,30s/div,60s/div 
120s/div 

Select time for 1 division of time axis. 

4.System 

General 

Brightness 

Brightness 

5 Bright 

5 Bright/4/3/2/1 Dark/0 Off 

Select brightness of display 
*”0 Off” is set, whole display is black out 

Power on delay 

PowerOnDelay 

None 

None/2Sec/5Sec/10Sec/20Sec/30Sec/60Sec 

Select time from power on to starting measurement 

Power saving time 

PowerSavingTime 

None 

None/1min/2 min/5 min/10 min/30 min/60 min 

In power saving state, brightness becomes “1 Dark” 
level. 

Language 

Language 

日本語

 

日本語

  /English 

Select language 

Direction of display 

DisplayDirection 

Horizontal 

Horizontal/Vertical 

Select direction of display 

Setting protect 

SettingProtect 

Disable 

Disable/Enable 

If Enable, changing settings are disabled. 

Pattern Copy 

PatternCopy 

Pattern5

source

 

PatternAll

destination

 

Excuse 

Pattern1/2/3/4/5/6/7/8 
Pattern1/2/3/4/5/6/7/8/PatternAll 
Operationselect Excuse 

Function of copying settings for each pattern. 

Initialize 

Save user defaults 

UserDefaultSave 

Message “Save current settings as user initial values?” 

 

Initialize to user 
defaults 

UserDefaultLoad 

Message “Initialize setting values to user initial values?” 

 

Initialize to factory 
default 

FactoryDefaultLoad 

Message “Initialize setting values to factory default?” 

 

5.Diagnosis 

Input Diagnosis 

Pulse input A Pulse 
input B 

PulseInputA   
PulseInputB 

 

 

Check for input signal existence. 
(Displays pulse counts

 

Analog input A Analog 

input B 

AnalogInputA 

AnalogInputB 

 

 

Check for input signal existence. 

(Displays level in percentage of rating.) 

External control 

inputs 

ExternalCtrl 

 

 

Check for ON/OFF state of terminals 

Output Test 

Comparative output 
AL1 to AL4 

CompareAL1 

CompareAL2   

CompareAL3 

CompareAL4 

 

 

Outputs ON level or OFF level 

Analog output 

AnalogOutput 

 

 

Outputs level of 10% steps of rating. 

BCD Output(Data) 
BCD Output(PC) 

BCD Output(Data) 
BCD Output(PC) 

 

 

Outputs ON level or OFF level for each bit 

Modbus

 

Communication 

RS-485 

ModbusCom 

 

 

Displays receive data and transmit data 

RS-232C 

RS-232C Com 

 

 

Displays receive data and transmit data 

1st layer 

Large categories

 

Summary of Contents for WPMZ-5

Page 1: ...Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same duct with lines including noises might cause malfunctions 4 The WPMZ becomes available functionally right after power activation but requires 30 minutes warming to satisfy all performance requirements Note The inputs A channel and B channel may be ...

Page 2: ...NE Ach Line driver input terminal 16 GND Ach GND input terminal 17 EXC Ach sensor power output terminal 18 EXC Ach sensor power output terminal 19 20 NC No connection Non usable for a relay terminal B channel line driver input terminal name description 21 LINE Bch Line driver input terminal 22 LINE Bch Line driver input terminal 23 GND Bch GND input terminal 24 EXC Bch sensor power output terminal...

Page 3: ...tive Indicates comparative output reset function an external control function is effective Indicates measurement inhibit function an external control function is effective Indicates display hold function an external control function is effective Indicates maximum value or minimum value hold function an external control function is effective 5 2 2 Key Operation Icons On The Setting Display Key oper...

Page 4: ...imes 8times 9times Set number of moving average Instantaneous value simple average InsSimpleAve None None 2 times 4 times 8 times 16 times 32 times 64 times 128 times 256 times Set number of simple average for internal sampling 10ms Instantaneous value display step InsDispStep None None 5steps 10steps Setting of steps of display If set to 5steps displayed only 0 or 5 on LSB WPMZ 5 L Pulse Input A ...

Page 5: ...0bps 19200bps 38400bps Set baudrate Data length DataLength 8bit 7bit 8bit Set data character length Parity Parity None None Even Odd Set parity bit Stop bit Stopbit 1bit 1bit 2bit Set stop bit length Delimiter Delimiter CR CR CR LF Set delimiter type 3 Display Display Select Measure select MeasureSelect 1input InsA 2inputs InsA InsB InsA InsB InsCalc InsA InsB InsCalc A B InsA Comp InsB Comp InsCa...

Page 6: ...ting items If the arrow key LEFT is pushed the display returns to the 2nd layer On the 3rd layer by pushing the MENU key the display returns to the measurement display By moving the cursor with arrow key UP DOWN select a setting item If the arrow key LEFT is pushed the display returns to the 2nd layer At the selected setting item by pushing arrow key RIGHT the display moves to the 4th layer settin...

Page 7: ...r 1 pulse as instantaneous display coefficient Although instantaneous flow rate will be displayed in ℓ min the rating of the sensor is 7 5 mℓ Pulse it should be converted to 7 5 10 3 ℓ Pulse Set the Instantaneous display factor as 7 50000 10 3 Displayed unit is ℓ min therefore select Minute as the instantaneous unit time By instantaneous decimal point position set the number of digits after the de...

Page 8: ...common for AL1 AL4 in open collector output products Each AL1 2 AL3 4 have common terminal in relay ouput products 11 3 COMPARISON JUDGEMENT VALUE The comparison judgement value is a threshold value to judge Although the setting procedure is same as 8 BASIC OPERATIONS FOR SETTING DISPLAY comparison judgement values need the settings of numerical values Therefore its procedure is shown below The fo...

Page 9: ...d Bch 12 7 PATTERN SELECT FUNCTION The pattern select function is the function which switches the pattern number to use for measurement By using pattern select 1 3 Up to 8 patterns can be switched Function Name Selected pattern No pattern No in use 1 2 3 4 5 6 7 8 Pattern select1 Open Short Open Short Open Short Open Short Pattern select2 Open Open Short Short Open Open Short Short Pattern select3...

Page 10: ...ys Please refer to 14 1 Locations of parameters for initialize 14 3 2 Initializing To User Defaults By executing to initialize to user defaults current setting values are replaced by user defaults Steps for the initialize operation are same as 14 2 Initializing to the factory defaults Operate the WPMZ according to the setting displays Please refer to 14 1 Locations of parameters for initialize 15 ...

Page 11: ... structure IP66 front Installation environment indoor use Rated altitude up to 2000m Transient overvoltage Ⅱ Measurement category Ⅱ Pollution degree 2 Conformed EN standard EN61326 1 EMS industrial electromagnetic environment EMI Class A Applicable to line length only under 30m EN61010 1 EN50581 Material of enclosure polycarbonate PC black UL94V 0 Input Specifications Pulse input instantaneous mea...

Page 12: ...ay value AL2 zone upper limit or AL2 zone lower limit display value AL2 display value AL3 zone upper limit or AL3 zone lower limit display value AL3 display value AL4 zone upper limit or AL4 zone lower limit display value AL4 Conversion method D A conversion method Resolution capability Equivalent of 13bit Scaling Digital scaling Output objective Response speed Specification for each output An ite...