Doc: WSP-038 IMU INSTALLATION MANUAL
Version: 1.4 December 2019
Doc: WSP-038 IMU INSTALLATION MANUAL
Version: 1.4 December 2019
wassp.com
wassp.com
WSP-038 IMU INSTALLATION MANUAL
WSP-038 IMU INSTALLATION MANUAL
4.3. DRX CONFIGURATION
Connect the WSP-038 and Satellite Compass to the DRX as per
“1 Interconnection
diagrams” on page 6.
AUX
N2K
POWER
LAN
0183
RS232
RS422-A RS422-B
Satellite Compass
WSP-038
Figure 4. S3/F3/F3X WSP-038 Connections
For sensor configuration on the DRX refer to the DRX Installation Manual.
Configure the DRX using the
DRX SETUP WEBPAGES.
Using the WSP-038
PRESET
the sensor setup can be automated for
PORT SETUP, DATA
SETUP, CORRECTIONS AND PPS
.
Sensor offsets will need to be input manually using the
SENSOR
configuration page.
Sensor biases (angular offsets) will need to be input manually using the
DATA SETUP
CONFIGURATION
page or using appropriate automated path tests.
Refer to the DRX Installation Manual for full details.
4.3.1. Configuring for WSP-038 with Furuno SC
1.
With the system fully connected with all sensors powered on open the
DRX SETUP
WEBPAGES.
2.
Select
CONFIGURATION
and open the
PRESETS
tab.
3.
Under
AVAILABLE PRESETS
select
SC WITH WSP-038
and
select
LOAD.
4.
Setup the sensor offsets
under the
SENSOR
tab,
following the instructions in
the DRX Installation Manual.
5.
Setup the Sensor Biases
under the
DATA SETUP
tab,
following the instructions in
the DRX Installation Manual.
Summary of Contents for WASP-038
Page 1: ...WASSP WSP 038 IMU INSTALLATION MANUAL...
Page 13: ......