7.1
Setting the correct Pressure
Before filling the tank, remove the accessories.
Afterwards set the correct polymerisation pressure.
Proceed as follows (image, see 7.2):
1. Activate main switch (green rocker switch).
2. Close lid.
3. Touch the Pressure key
(image, see 7.2).
(2.5 bar default)
.
4. If the pressure is very less (
min. 2 bar
), increase the pressure (
max. 6 bar
) using
the black regulator on the back side. Release the regulator by pulling to do the
setting and press it in once again.
5. If the pressure is too high, switch off the pressure
(image, see 7.2) and release
the pressure. Turn the pressure regulator on the back side in the "minus" direction
several times; then, apply pressure to the tank. You can set the desired pressure by
turning the regulator in the "plus" direction.
For safety reasons, the pressure setting is limited to max. 6 bar (at 20 ° C).
For an optimal pressure setting, the device should be brought up to
working temperature beforehand.
9