Wasserhaus Deutschland GmbH· Max-Wundel-Strasse 12 · D-14469 Potsdam ·
Tel. 0331 – 505 79 43 · Fax 0331 – 505 79 52
www.wasserhaus.de · e-mail: [email protected]
page
4
Depth
44 cm
Parameters
Parameter
Limit value
Water pressure
3 - 6 bar (0,8 – 6 bar for RO5 Booster and
RO7)
Water temperature
12 – 50° C
Total Dissolved Solids (µS)
max. 2000
PH value
3-10
free Chlorine
1,0 ppm max.
Product (quality) water/24 hrs
24 hrs* 50, 75 or 100 gal.
Percent rejection of TDS,
minimum (new membrane) 90 – 95
Storage tank capacity (maximum)
2G, 3.2G or 4G
Safety Guides
Read all steps and guides carefully before installing and using your reverse osmosis system.
Follow all steps exactly to correctly install.
Reading this manual will also help you get all the benefits from your RO system.
DO NOT attempt to use this product to make safe drinking water from non-potable water
sources. Do not use the system on microbiologically unsafe water, or water of unknown
quality without adequate disinfection before or after the system. This system is suitable for
cyst reduction and may be used on disinfected water that may contain filterable cysts.
Check with your local public works department for plumbing and sanitation codes. You must
follow their guides as you install the system. Follow your local codes if they differ with guides
in this manual.
This reverse osmosis system works on water pressure of 2,8 bar (32 psi) (minimum) to 6 bar
(87 psi) (maximum). You must install a pressure reducing valve in the water supply pipe to
the reverse osmosis system if the water pressure exceeds 6 bar (87 psi).
Do not install this reverse osmosis system outside or in extreme hot or cold environments.
Temperature of the feed water supply to the RO system must be between 4° C and 45° C.
Do not install on hot water.
The reverse osmosis membrane contains a food grade preservative for storage and
shipment. Be sure to purge it as instructed on page 15.
Where to install the RO system
This RO system is designed for installation under the sink, usually in the kitchen or
bathroom. The RO system can be mounted on a wall surface or can lie on the cabinet floor
next to the storage tank. The RO faucet installs on the sink, into the counter next to the sink
or in the special bracket on the wall.
You can also install the system in any remote location from the faucet, observing the safety
guides on page 4. You will need a nearby water supply and drain point.
Water supply: To provide supply water to the RO system inlet, use the included feed supply
fittings as described on page 9.
Drain Point: A suitable drain point is needed for the reject water from the RO membrane. A
floor drain, laundry tub, standpipe, sump, etc., is preferred for remote installations. A saddle
drain adapter is included to install the system under the sink where codes permit, as an
optional drain point.