Plessey
ENTER/EXIT PROGRAMMING MODE
216
WLS9600
Plessey Set Length 1
This feature specifies one of the barcode lengths for
Plessey Length Control
. Length 1 is the
minimum label length if in
Variable Length
Mode, or the first fixed length if in
Fixed Length
Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50
characters.
Table
26
provides some examples for setting Length 1. See
page 242
for detailed instructions on
setting this feature.
Table 26. Plessey Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the
entry string. You can then start again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Summary of Contents for WLS9600
Page 1: ...WLS9600 1D Laser Scanner USB Product Reference Guide ...
Page 10: ...Contents 8 WLS9600 NOTES ...
Page 14: ...Introduction 4 WLS9600 NOTES ...
Page 24: ...Setup 14 WLS9600 NOTES ...
Page 28: ...Global Interface Features ENTER EXIT PROGRAMMING MODE 18 WLS9600 NOTES ...
Page 42: ...ENTER EXIT PROGRAMMING MODE 32 WLS9600 NOTES ...
Page 86: ...Scanning Features ENTER EXIT PROGRAMMING MODE 76 WLS9600 NOTES ...
Page 236: ...Code 4 and Code 5 Common Configuration Items ENTER EXIT PROGRAMMING MODE 226 WLS9600 NOTES ...
Page 268: ...References 258 WLS9600 NOTES ...
Page 274: ...Technical Specifications 264 WLS9600 NOTES ...
Page 288: ...Sample Barcodes 278 WLS9600 NOTES ...
Page 291: ...Keypad Product Reference Guide 281 A B C D E F ...
Page 292: ...Keypad 282 WLS9600 NOTES ...
Page 302: ...Scancode Tables 292 WLS9600 NOTES ...