background image

Programming

18

WDI4200

Caps Lock State

This option specifies the format in which the reader sends 
character data. This applies to keyboard wedge interfaces. 
This does not apply when an alternate key encoding key-
board is selected.

CAPS LOCK STATE

ENTER/EXIT PROGRAMMING MODE



Caps Lock State = Caps Lock OFF

Caps Lock State = Caps Lock ON

Caps Lock State = AUTO Caps Lock Enable



= default value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for WDI4200

Page 1: ...Wasp WDI4200 2D USB Barcode Scanner Quick Reference Guide ...

Page 2: ... provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Wasp Technologies publications please let us know via the Contact WaspTechnologies page Disclaimer Wasp Technologies has taken reasonable measures to provide informantion in this manual that is complete and accurate how ever Wasp Technologies reserves the right to change any s...

Page 3: ...guring the Interface 6 Keyboard Interface 9 Scancode Tables 11 Country Mode 11 Programming 16 Using Programming Bar Codes 16 Configure Other Settings 16 Resetting Product Defaults 16 Numlock 17 Caps Lock State 18 Reading Parameters 19 Aiming System 19 Good Read Green Spot Duration 19 Operating Modes 20 Scan Mode 20 Pick Mode 22 Multiple Label Reading 22 Technical Features 23 LED and Beeper Indicat...

Page 4: ...ii WDI4200 ...

Page 5: ...blicense rent loan lease assign export re export resell ship or divert or cause to be exported re exported resold shipped or diverted directly or indirectly the Software under this Agreement End User shall not and shall not permit others to i modify translate decompile reverse engineer disassemble or extract the inner workings of the Software ii copy the functionality of the Wasp Products iii remo...

Page 6: ... of its component parts and upon request provide an affidavit certifying your compliance with the foregoing The provisions of Sub sections 1 2 1 3 1 4 1 5 4 5 6 8 and 12 shall survive termination of this Agreement 4 Limited Warranty Wasp warrants that under normal use and operation the Software will conform substantially to the applicable Wasp Product documentation for the period specified in the ...

Page 7: ...re by the U S Government is subject to the restrictions for computer software developed at private expense as set forth in the U S Federal Acquisition Regulations at FAR 52 227 14 g or 52 227 19 or in the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 c 1 ii whichever is applicable 8 2 If End User is using the Wasp Product outside of the United States End User must com...

Page 8: ...Agreement Amendment This document contains the entire agreement between the parties relating to use of the Wasp Products and the licensing of the Software and supersedes all prior or contemporaneous agreements written or oral between the parties concerning the use of the Wasp Products and licensing of the Software This Agreement may not be changed amended or modified except by written document sig...

Page 9: ...contract including any question regarding its existence validity or termination shall be referred to and finally resolved by arbitration administered by the Singapore International Arbitration Centre SIAC in accordance with the Arbitration Rules of the Singapore International Arbitration Centre SIAC Rules for the time being in force which rules are deemed to be incorporated by reference in this cl...

Page 10: ...viii WDI4200 NOTES ...

Page 11: ...ufacturing Document Bill Processing and Bank ing Finance The WDI4200 2D imager is the most afford able area imager with the best performance in its class Hands Free Stand Holder An accessory is available which holds the reader at a con venient angle allowing hands free scanning of items It can also be used as a holder Always press in on the release buttons on both sides of the stand to raise the a...

Page 12: ...w to connect and get your reader up and communicating with its host 1 Connect the Cable to the reader and the Host as shown below 2 Configure the Interface see page 6 3 Program the Reader starting on page 19 optional as needed Connecting to the Host Interface USB WEDGE RS 232 ...

Page 13: ...200 The Wasp WDI4200 normally functions by capturing and decoding codes The aiming system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code Aiming System Relative Size and Location of Aiming System Pattern 2D Matrix Symbol ...

Page 14: ...l size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is centered you will get a good read Successful reading is signaled by an audible tone plus a goodread green spot LED indicator Reference the Wasp WDI4200 Product Reference Guide PRG on the Wasp website for more information about this feature and othe...

Page 15: ...Parts of the Reader Quick Reference Guide 5 Parts of the Reader 1 LED 3 Scan Window 2 Cable Release Hole 4 Trigger 1 2 3 4 ...

Page 16: ...mposite Keyboard COM Keyboard Wedge Information and programming options for each interface type are provided in this section For defaults and addi tional information associated with each interface proceed to the corresponding chapter in the Wasp WDI4200 PRG Configuring the Interface Scan the appropriate programming bar code to select the interface type for your system NOTE Unlike some other progra...

Page 17: ...tandard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STD default value Download the correct USB Com driver from www waspbarcode com ...

Page 18: ...Selecting the Interface Type 8 WDI4200 USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM USB COMPOSITE USB Composite Select USB Composite ...

Page 19: ...tions for USB Keyboard and Wedge Interfaces KEYBOARD AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT ...

Page 20: ... continued Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Select KBD AT ALT NK USB Keyboard with standard key encoding Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard ...

Page 21: ... key encoding USB Keyboard with standard key encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY the f...

Page 22: ...ce Type 12 WDI4200 COUNTRY MODE continued Country Mode Belgium Country Mode Croatia Country Mode Czech Republic Country Mode Denmark default value Supports only the interfaces listed in the Country Mode feature description ...

Page 23: ...Selecting the Interface Type Quick Reference Guide 13 COUNTRY MODE continued Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy CKBCO13 CR ...

Page 24: ...pe 14 WDI4200 COUNTRY MODE continued Country Mode Japanese 106 key Supports only the interfaces listed in the Country Mode feature description Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal ...

Page 25: ...continued Country Mode Romania Country Mode Spain Supports only the interfaces listed in the Country Mode feature description Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature description ...

Page 26: ...e to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installa tion requires different programming than the standard factor...

Page 27: ... setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard NUMLOCK ENTER EXIT PROGRAMMING MODE Numlock Numlock key unchanged Numlock Numlock key toggled default value ...

Page 28: ...r sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected CAPS LOCK STATE ENTER EXIT PROGRAMMING MODE Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable default value ...

Page 29: ... will remain on until the symbol is decoded As you read code symbols adjust the distance at which you are holding the reader Aiming System A number of options for customizing control of the Aiming Sys tem are available See the Wasp WDI4200 PRG for more infor mation and programming bar codes Good Read Green Spot Duration Successful reading can be signaled by a good read green spot Use the bar codes...

Page 30: ...ime 1 has elapsed Reading a label does not disable scanning Double Read Timeout1 prevents unde sired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elapsed Read ing a label does not disable scanning Double Read Time out1 prevents undesired multiple reads while in t...

Page 31: ...ding area If a predefined amount of movement is detected the white illumination switches on Scanning continues until a label is read or maximum scan on time is reached SCAN MODE ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode default value ...

Page 32: ...ledged or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Label Reading The reader offers a number of options for multiple label reading See the PRG or software configuration tool for descriptions of these features and programming labels NOTE This feature is not compa...

Page 33: ...stem LED source White Emission wavelength 350 770 nm IEC 62471 Exempt Risk Group Aiming System LED source Blue emission wavelength 470nm Pulsed source pulsed with 10 ms duration 50 duty cycle IEC 62471 Risk Group 1 Ambient Light Up to 92000 lux Tilt Tolerance 0 360 Pitch Tolerance 65 Skew Tolerance 65 Field of View 48 H x 37 V DOF Depth of Field Typical Code 39 5 mils 0 5 to 12 5 cm 0 2 to 4 9 in ...

Page 34: ...sey Anker Plessey GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Truncated DATABAR Expanded Coupon 2D Stacked Codes The Wasp WDI4200 scanner is capable of decoding the following sym bologies using multiple frames i e Multi Frame Decoding Datamatrix Inverse Datamatrix Datamatrix is configurable for the fol lowing parameters Normal or Inverted Square or Rectangular ...

Page 35: ...e LED blinks until enumeration with the host is completed Imager beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behavior for this indi cation is configurable using Aladdin utility One beep at current fre quency volume mono bi tonal setting upon a suc cessful label scan It is also possible to upload custom jingles wi...

Page 36: ...type Ensure imager is pro grammed to read the type of bar code scanned Refer to the PRG for more informa tion Bar code label is unreadable Check the label to ensure it is not defaced Try scanning another bar code type Distance between imager and bar code is incorrect Move imager closer to or further from the bar code Bar code is decoded but not transmitted to the host Imager not pro grammed for th...

Page 37: ...rs Wasp may use new or reconditioned parts components subassemblies or products that have been tested as meeting applicable specifi cations for equivalent new material and products Customer will allow Wasp to scrap all parts removed from the repaired product The warranty period shall extend from the date of shipment from Wasp for the duration published by Wasp for the product at the time of purcha...

Page 38: ... degradation and or viii any consumable or equivalent e g cables power supply bat teries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under this warranty except to a purchaser or transferee of product No attempted assignment or transfer in violation of this provision shall be valid or binding upon Wasp WASP S LIMITED WARRA...

Page 39: ... workstations Provide adequate clearance Provide a suitable working environment Improve work procedures Services and Support Wasp Technologies provides several services as well as technical support through its website Log on to www waspbarcode com and click on the links indicated for further information CAUTION In order to avoid or minimize the potential risk of ergonomic injury follow the recomme...

Page 40: ...cloth or lint free cleaning tissues dampened with a non abrasive mild water based glass cleaner The other sur faces can also be cleaned using the same cleaning agents Do not allow fluids to flow into the internal parts of the scanner CAUTION DO NOT use abrasive pads or cleaning agents ...

Page 41: ...Cleaning Quick Reference Guide 31 NOTES ...

Page 42: ...Cleaning 32 WDI4200 NOTES ...

Page 43: ......

Page 44: ...hts reserved WASP logo are registered trademarks of WASP in many countries including the U S A and the E U Wasp Barcode Technologies 1400 10th Street Plano Texas USA 75074 Telephone 214 547 4100 www waspbarcode com 820101014 Rev A April 2018 ...

Reviews: