49
If water continues to fill without stopping.
A Check hose attached to level control unit.
B Check inlet valves for dirt underneath the
valve diaphragm. To localize, shut off power.
If water continues to flow, inlet valves have
foreign material in them and should be tho-
roughly cleaned.
If water continues to flow without filling
machine.
A Check seating of drain valve.
Trouble shooting