![Wascomat Flex-O-Matic FL 125 Operating & Maintenance Manual Download Page 13](http://html.mh-extra.com/html/wascomat/flex-o-matic-fl-125/flex-o-matic-fl-125_operating-and-maintenance-manual_873596013.webp)
9
Installation
Drain connection
Connect a 3" (75 mm) flexible drain hose to the
drain outlet of the machine.
The drain hose must not have sharp bends and
must slope from the machine to assure proper
drainage.If the machine(s) drain into an open
trough the trough should have a slope of 1/8"-
1/4" per foot towards the main drain.
Note:
To simplify installation, Wascomat has made
availalble the following hose kits:
For FL 125 Partno. 002008
For FL 185 Partno. 002009
These kits contain inlet hoses, drain hose, hose
clamps and washers.
Steam connections (optional steam heating)
The steam supply to the machine should be fitted
with manual shut-off valves and filters to facilitate
installation and servicing.
Fit the filter supplied to the manual cut-off valve.
The connection hose must be of type ISO/1307-
1983 or equivalent. Connection size at filter: DN
15 (BSP 1/2'').
Steam pressure required:
•
minimum: 10 psi (0.5 kp/cm
2
)
•
maximum: 115 psi (8 kp/cm
2
)
Check that there are no sharp angles or bends in
the connection hose.
For steam pressures in excess of 85 psi, the
nozzle supplied should be installed between the
stem injector and the steam hose. The nozzle is
installed inside the steam injector.
14
1833
16
2171
15
0956
Fig.
14
Fig.
15
Fig.
16