Fuel feed system - HFO installations
Figure 6.12
Example of fuel oil system (HFO), multiple engine installation (DAAE085365B)
System components:
Circulation pump (booster unit)
1P06
Heater (booster unit)
1E02
Circulation pump (HFO, MDF)
1P12
Cooler (booster unit)
1E03
Pilot fuel feed pump (MDF)
1P13
Cooler (MDF)
1E04
Day tank (HFO)
1T03
Safety filter (HFO)
1F03
Leak fuel tank (clean fuel)
1T04
Fine filter (MDF)
1F05
Day tank (MDF)
1T06
Suction filter (booster unit)
1F06
Leak fuel tank (dirty fuel)
1T07
Suction strainer (MDF)
1F07
De-aeration tank (booster unit)
1T08
Automatic filter (booster unit)
1F08
Changeover valve
1V01
Flow meter (booster unit)
1I01
Pressure control valve (booster unit)
1V03
Viscosity meter (booster unit)
1I02
Overflow valve (HFO/MDF)
1V05
Feeder / Booster unit
1N01
Overflow valve (HFO/MDF)
1V05-1
Pump and filter unit (HFO/MDF)
1N03
Venting valve (booster unit)
1V07
Fuel feed pump (booster unit)
1P04
Pipe connections:
Leak fuel drain, dirty fuel
104
Fuel inlet
101
Pilot fuel inlet
112
Fuel outlet
102
Pilot fuel outlet
117
Leak fuel drain, clean fuel
103
Product Guide Wärtsilä 34DF - 3/2012
61
Product Guide
6. Fuel System