Figure 7.5
Example of system oil tank arrangement (DAAE007020e)
Design data:
1.2...1.5 l/kW, see also Technical data
Oil tank volume
75...80% of tank volume
Oil level at service
60% of tank volume
Oil level alarm
7.3.3 New oil tank (2T03)
In engines with wet sump, the lubricating oil may be filled into the engine, using a hose or an oil can, through
the crankcase cover or through the separator pipe. The system should be arranged so that it is possible
to measure the filled oil volume.
7.3.4 Suction strainers (2F01, 2F04, 2F06)
It is recommended to install a suction strainer before each pump to protect the pump from damage. The
suction strainer and the suction pipe must be amply dimensioned to minimize pressure losses. The suction
strainer should always be provided with alarm for high differential pressure.
Design data:
0.5...1.0 mm
Fineness
76
Product Guide Wärtsilä 34DF - 3/2012
Product Guide
7. Lubricating Oil System