where:
total starting air vessel volume [m
3
]
V
R
=
normal barometric pressure (NTP condition) = 0.1 MPa
p
E
=
air consumption per start [Nm
3
] See Technical data
V
E
=
required number of starts according to the classification society
n =
maximum starting air pressure = 3 MPa
p
Rmax
=
minimum starting air pressure = See Technical data
p
Rmin
=
NOTE
The total vessel volume shall be divided into at least two equally sized starting air
vessels.
8.3.4
Air filter, starting air inlet (3F02)
Condense formation after the water separator (between starting air compressor and starting
air vessels) create and loosen abrasive rust from the piping, fittings and receivers. Therefore
it is recommended to install a filter before the starting air inlet on the engine to prevent particles
to enter the starting air equipment.
Wärtsilä 31 Product Guide - a1 - 18 October 2016
8-5
8. Compressed Air System
Wärtsilä 31 Product Guide
Summary of Contents for 31
Page 1: ...PRODUCT GUIDE W rtsil 31...
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 36: ...This page intentionally left blank...
Page 44: ...This page intentionally left blank...
Page 88: ...This page intentionally left blank...
Page 116: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 148: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 162: ...This page intentionally left blank...
Page 165: ......
Page 166: ......
Page 167: ......