Each engine must have its own vent pipe into open air. The crankcase ventilation pipes may
not be combined with other ventilation pipes, e.g. vent pipes from the system oil tank.
The diameter of the pipe shall be large enough to avoid excessive back pressure. Other possible
equipment in the piping must also be designed and dimensioned to avoid excessive flow
resistance.
A condensate trap must be fitted on the vent pipe near the engine.
The connection between engine and pipe is to be flexible.
Design data:
see Technical data
Flow
see Technical data
Backpressure, max.
80°C
Temperature
Fig 7-6
Condensate trap
(DAAE032780B)
The size of the ventilation pipe (D2) out
from the condensate trap should be
bigger than the ventilation pipe (D) com-
ing from the engine.
For more information about ventilation
pipe (D) size, see the external lubricating
oil system drawing.
The max. back-pressure must also be
considered when selecting the ventilation
pipe size.
7-12
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Wärtsilä 31 Product Guide
7. Lubricating Oil System
Summary of Contents for 31
Page 1: ...PRODUCT GUIDE W rtsil 31...
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 36: ...This page intentionally left blank...
Page 44: ...This page intentionally left blank...
Page 88: ...This page intentionally left blank...
Page 116: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 148: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 162: ...This page intentionally left blank...
Page 165: ......
Page 166: ......
Page 167: ......