3.5
Wärtsilä 16V31
ME
IMO Tier 2
AUX
IMO Tier 2
AUX
IMO Tier 2
DE
IMO Tier 2
DE
IMO Tier 2
Wärtsilä 16V31
750
610
750
610
720
590
750
610
720
590
RPM
kW/cyl
Engine speed
Cylinder output
9760
9760
9440
9760
9440
kW
Engine output
3.01
3.01
3.03
3.01
3.03
MPa
Mean effective pressure
Combustion air system (Note 1)
17.27
17.27
16.65
17.27
16.65
kg/s
Flow at 100% load
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
65
65
65
65
65
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
17.76
17.76
17.12
17.76
17.12
kg/s
Flow at 100% load
15.04
15.2
14.56
15.2
14.56
kg/s
Flow at 85% load
12.96
13.6
13.12
13.6
13.12
kg/s
Flow at 75% load
9.12
10.4
9.92
10.4
9.92
kg/s
Flow at 50% load
273
273
275
273
275
°C
Temperature after turbocharger, 100% load (TE 517)
277
275
277
275
277
°C
Temperature after turbocharger, 85% load (TE 517)
295
282
284
282
284
°C
Temperature after turbocharger, 75% load (TE 517)
320
286
288
286
288
°C
Temperature after turbocharger, 50% load (TE 517)
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
997
997
981
997
981
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
989
989
920
989
920
kW
Jacket water, HT-circuit
1851
1851
1717
1851
1717
kW
Charge air, HT-circuit
2459
2459
2390
2459
2390
kW
Charge air, LT-circuit
1045
1045
974
1045
974
kW
Lubricating oil, LT-circuit
274
274
262
274
262
kW
Radiation
For optional engineversions heat balances may differ
Fuel system (Note 4)
1000±100
1000±100
1000±100
1000±100
1000±100
kPa
Pressure before injection pumps (PT 101)
120.0
120.0
120.0
120.0
120.0
m
3
/h
Engine driven pump capacity (MDF only)
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
°C
HFO temperature before engine, max. (TE 101)
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
°C
MDF temperature before engine, max. (TE 101)
174.4
174.9
174.0
174.4
173.5
g/kWh
Fuel consumption at 100% load, HFO
171.7
172.0
171.1
171.6
170.6
g/kWh
Fuel consumption at 85% load, HFO
171.7
174.0
173.0
173.5
172.5
g/kWh
Fuel consumption at 75% load, HFO
178.6
183.8
182.8
183.3
182.3
g/kWh
Fuel consumption at 50% load, HFO
173.5
174.0
173.0
173.5
172.5
g/kWh
Fuel consumption at 100% load, MDF
170.7
171.1
170.1
170.6
169.7
g/kWh
Fuel consumption at 85% load, MDF
170.7
173.0
172.0
172.5
171.6
g/kWh
Fuel consumption at 75% load, MDF
Wärtsilä 31 Product Guide - a1 - 18 October 2016
3-13
3. Technical Data
Wärtsilä 31 Product Guide
Summary of Contents for 31
Page 1: ...PRODUCT GUIDE W rtsil 31...
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 36: ...This page intentionally left blank...
Page 44: ...This page intentionally left blank...
Page 88: ...This page intentionally left blank...
Page 116: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 148: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 162: ...This page intentionally left blank...
Page 165: ......
Page 166: ......
Page 167: ......