Page 8
For technical questions, please call 1-888-866-5797.
Item 57342
Sa
FE
ty
Op
E
ra
ti
O
n
Maint
E
nanc
E
S
E
tup
Specifications
Electrical Rating
120VAC / 60Hz / 15A
Rated No Load Speed
4250/min
Cutting Capacity at 0°
3-3/16"
Cutting Capacity at 45°
2-3/16"
Maximum Bevel
45°
Maximum Miter
90°
Saw Blade (sold separately) 10" (254mm) Diameter, 7/64" Wide
5/8" Diamond Arbor
Setup - Before use:
read the EntirE iMpOrtant SaFEty inFOrMatiOn section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
tO prEVEnt SEriOuS inJury FrOM acciDEntaL OpEratiOn:
turn the power Switch of the tool off and unplug the tool from its electrical outlet before performing any
procedure in this section.
note:
For additional information regarding the parts listed in the
following pages, refer to
Parts List and Diagram
on page 20.
Mounting
note:
Table Saw MUST be mounted
onto a surface for proper use.
if mounting onto a metal table stand:
1. Select a table stand which will support
the weight of the Table Saw. Follow the
table saw stand instructions for assembly.
Tighten all connections, making sure the
assembled table is secure and balanced.
2. Mount the Table Saw to the top of the assembled
stand using four 3/8″ bolts, eight 3/8″ washers
and four 3/8″ nuts (not included).
if mounting onto a bench or other wooden surface:
1.
Select four 3/8″ bolts, eight 3/8″ washers, and
four 3/8″ nuts* (not included).
*
Screws and washers may be used instead, if desired.
2. Place the Table Saw where it will be mounted.
Make a mark in the center of each of the
4 mounting holes. Set the Saw aside.
WarninG! tO prEVEnt SEriOuS inJury:
Before drilling the holes, make sure that there
are no electric wires, cables, utility lines or
other obstructions in the area to be drilled.
3. Drill the holes straight down, large enough
to allow your mounting hardware to fit.
4. Put the Table Saw in place and mount
using the hardware mentioned above.
Tighten all hardware securely before use
.
power Supply requirements
1. Connect to grounded 120VAC, 20A receptacle.