background image

Model EH2-M & SH2-M  Page 4 

eh2-sh2dl4sm-rev0614

TROUBLE SHOOTING

1. Pump will not cycle

A. Check to make sure the unit has enough pressure to operate and that the air 

inlet valve is open.

B. Check the discharge line to insure that the discharge line is neither closed nor 

blocked.

C. If the spool in the air distribution valve is not shifting check the main spool. It 

must slide freely.

D. Excessive air leakage in the pump can prevent cycling. Air leakage from the 

exhaust port indicates leakage in the air distribution valve. See further service instruc-

tions.

E. Blockage in the liquid chamber can impede movement of diaphragm.

2. Pump cycles but will not pump

A. Suction side of pump pulling in air. Check the suction line for air leaks and be 

sure that the end of the suction line is submerged. Check flange bolting. Check valve 

flanges and manifolds to chamber flange joints. 

B. Make certain the suction line or strainer is not plugged. Restriction at the suc-

tion is indicated by a high vacuum reading when a vacuum gauge is installed in the 

suction line. 

C. Check valves may not be seating properly. To check, remove the suction line and 

cover the suction port with your hand. If the unit does not pull a good suction (vacuum), 

the check valves should be inspected for proper seating.

D. Static suction life may be too high. Priming can be improved by elevating the 

suction and discharge lines higher than the check valves and pouring liquid into the 

unit through the suction inlet. When priming at high suction lifts or with long suction 

lines operate the pump at maximum cycle rate.

3. Low performance

A.  Capacity  is  reduced  as  the  discharge  pressure  increases.  Performance  

capability varies with available inlet supply. Check air pressure at the pump inlet when 

the pump is operating to make certain that adequate air supply is maintained. 

B. Check vacuum at the pump suction. Capacity is reduced as vacuum increas-

es.  Reduced  flow  rate  due  to  starved  suction  will  be  evident  when  cycle  rate  can 

be varied without change in capacity. This condition will be more prevalent when  

pumping viscous liquids. When pumping thick, heavy material the suction line must 

be kept as large in diameter and as short as possible, to keep suction loss minimal. 

C.  Low  flow  rate  and  slow  cycling  rate  indicate  restricted  flow  through  the  

discharge line. Low flow rate and fast cycling rate indicate restriction in the suction line 

or air leakage into suction. 

For more information, refer to the Warren Rupp Troubleshooting Guide.

WARRANTY:

 This unit is guaranteed for a period of five years against defective 

material and workmanship. 

For high pressure pumps used in conjunction with another diaphragm pump in “skid 

mount” system: The EH2-M will not prime against the head created by the fill pump. 

Run both simultaneously at start-up.

RECOMMENDED WARREN RUPP

®

 ACCESSORIES 

TO MAXIMIZE PUMP PERFORMANCE:

• Tranquilizer

®

 Surge Suppressor. For nearly pulse-free flow.

• Warren Rupp Air Dryer. For clean, dry compressed air.
• Warren Rupp Filter/Regulator. For modular installation and 

service convenience.

• Warren Rupp Speed Control. For manual or programmable 

process control. Manual adjustment or 4-20mA reception.

For more detailed information on these accessories, contact your local 

Warren Rupp Factory-Authorized Distributor, or Warren Rupp corporate 

headquarters.

Summary of Contents for SANDPIPER EH2-M

Page 1: ...an air supply of rigid piping mount a section of flexible line to the pump to eliminate piping strain In permanent installations an air line filter is recommended FREEZING OR ICING OF EXHAUST Icing o...

Page 2: ...eal Inspect for flat spots and gouges Behind the seal is an energizer ring that helps to load the seal against the cylinder wall The energizer ring is included with the new seal The wear rings are the...

Page 3: ...mage the sleeve At this point inspect the o rings on the sleeve for nicks tears or abrasions Damage of this sort could happen during assembly or servicing A sheared or cut o ring can allow the pump s...

Page 4: ...aximum cycle rate 3 Low performance A Capacity is reduced as the discharge pressure increases Performance capability varies with available inlet supply Check air pressure at the pump inlet when the pu...

Page 5: ...ile 363 FKM Color coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane List continued next page 1 008 013 080...

Page 6: ...asher Lock EH2 CI Models 18 EH2 SS Models 20 50 132 022 360 Bumper goes to head of item 38 2 51 901 005 330 Washer Flat EH2 only 6 52 050 005 354 Ball Check Valve EH2 CI Only 2 050 005 360 Ball Check...

Page 7: ...up Diaphragm PTFE Overlay Diaphragm Check Balls and O Rings Stainless Steel Seats 476 056 360 WETTED END KIT SS Only Buna Diaphragm Check Balls and O Rings Stainless Steel Seats 476 056 364 WETTED END...

Page 8: ...ric diaphragms as shown Torque the outer plate to the hex nut item 68 utilizing the lock washer item 67 Torque at 40 ft lbs 54 23 Newton meters Fill the fluid cell as specified in the DIAPHRAGM SERVIC...

Page 9: ...NO DESCRIPTION QTY 9 115 067 080 Mounting Bracket Assembly 1 16 170 024 330 Hex Head Capscrew 2 20 170 052 330 Hex Head Capscrew 6 21 170 057 330 Hex Head Capscrew 2 22 170 060 330 Hex Head Capscrew...

Page 10: ...d Double Diaphragm Pump Series HDB HDF M Non Metallic S Non Metallic M Metallic S Metallic T Series G Series RS Series U Series EH and SH High Pressure W Series SMA and SPA Submersibles and Tranquiliz...

Page 11: ...e Diaphragm Pumps Manufacturer Warren Rupp Inc A Unit of IDEX Corportion 800 North Main Street P O Box 1568 Mansfield OH 44901 1568 USA Applicable Standard EN13463 1 2001 EN13463 5 2003 II 2 GD c T5 I...

Reviews: