background image

2

Warner Electric • 800-234-3369

P-272A • 819-0527

Contents

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Reorder Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Template for Mounting . . . . . . . . . . . . . . . . . . . . . . . . . 6
System Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . 7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . back cover

The CBC-700's sophisticated coil suppression
circuitry allows extremely short time delays and
quick response. Optically isolated switching
inputs promote full switching flexibility.

The

CBC-700-90

incorporates several new

features:

A short circuit protection for the clutch and
brake outputs. If a short is present, an amber
L.E.D. will illuminate and the outputs will be
isabled. The short circuit L.E.D. is reset by
turning off the power to the control for 10
seconds.

• An O.E.X. on/off switch allows the user to

turn off the O.E.X. pulse for custom
applications.

• Two output L.E.D.s indicate when the brake

(red) or clutch (green) is on.

Introduction

Warner Electric's CBC-700 clutch/brake
control is a basic overexcitation control for
electromagnetic clutches and brakes.
Overexcitation, a momentary high voltage spike,
builds up electromagnetic flux very quickly in
the clutch and/or brake coil for quick
engagement and superior accuracy. The
CBC-700 works on the capacitive discharge
principle, boosting AC input voltage and storing
a high voltage pulse. No torque adjustment is
provided, so full torque is available from the
"on" clutch (or brake) by providing it with full
rated voltage. Two models of the CBC-700 are
available:

CBC-700-90

90 volt magnets

CBC-700-24

24 volt magnets

The

CBC-700

requires only two adjustments.

Overexcitation pulse duration is adjustable in
seven ranges to custom tailor control function
for each application and to minimize coil
temperatures. A time delay between
clutch/brake engagement is also adjustable
between 0 and 100 milliseconds for the
CBC-700-90, and 0 to 50 milliseconds for the
CBC-700-24, by providing a rest period
between brake and clutch engagement. This
eliminates overlap and reduces heating and
wear of the clutch and brake units.

Failure to follow these

instructions may result in product damage,
equipment damage, and serious or fatal
injury to personnel.

®

DIST. AUTORIZADO

MEX (55) 53 63 23 31
QRO (442) 1 95 72 60

MTY (81) 83 54 10 18
[email protected]

Summary of Contents for CBC-700-90

Page 1: ...nstructions P 272A 819 0527 CBC 700 Series Overexcitation Clutch Brake Controls An Altra Industrial Motion Company DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas indus...

Page 2: ...a momentary high voltage spike builds up electromagnetic flux very quickly in the clutch and or brake coil for quick engagement and superior accuracy The CBC 700 works on the capacitive discharge pri...

Page 3: ...2 3 4 All Open Time milliseconds 8 11 15 22 34 50 100 OEX Pulse Duration early model without OEX on off switch Switch Position 1 2 1 2 3 2 3 4 3 4 Time Milliseconds 7 10 15 22 34 51 100 Anti Overlap...

Page 4: ...nal contact closure for the start signal and a sensor to initiate braking 4 50 114 3 1 85 47 2 50 63 5 5 00 127 3 25 82 5 4 65 118 1 0 125R TYP 3 2 0 50 12 7 0 50 12 7 6 PLS 0 20 5 1 0 95 24 0 100 R T...

Page 5: ...Clutch OEX Switch Overlap Pot Brake CBC 700 24 CBC 700 24 Model Switches On SF PB 120 1 0 SF PB 170 1 0 SF PB 250 1 3 SF PB 400 2 10 SF 500 2 16 PC PB 500 2 3 10 SF 650 3 4 18 PB 650 2 16 SF 825 3 4...

Page 6: ...6 Warner Electric 800 234 3369 P 272A 819 0527 Template for Mounting CBC 700 Base Mount Wall Mount DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com...

Page 7: ...Improper AC line voltage Check line voltage and correct if necessary Improper magnet voltage Check magnet voltage rating and replace with correct magnet if necessary Symptom D Magnets do not appear t...

Page 8: ...llation operation or maintenance Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you Warner Electric LLC s obligation under this warr...