background image

3

Warner Electric • 800-234-3369

P-272A • 819-0527

Specifications

Input:

CBC-700-90:

120 VAC ± 10%, 50/60 Hz

CBC-700-24:

24 VAC ± 10%, 50/60 Hz

Output Voltage:

Steady State:

CBC-700-90:

90 VDC

CBC-700-24:

24 VDC

Overexcitation:

CBC-700-90:

340 VDC

CBC-700-24:

105 VDC

Output Current: (per channel, alternately)

CBC-700-90:

0.5 Amps max.*

CBC-700-24:

3.5 Amps max.

Circuit Protection: (fusing)

CBC-700-90:

1.6 Amp, 250 Volt, 5 x 20 mm, F/A

CBC-700-24:

5 Amp, 250 Volt, 5 x 20 mm, F/A

* Caution: It will not work with the SF1525HT-90

OEX Pulse Duration: (current model–with OEX on/off switch)

700-24 Switch Position

1 & 2

1

2 & 3

2

3 & 4

3

4

700-90 Switch Position

1 & 2

1

2 & 3

2

3

4

All Open

Time (milliseconds)

8

11

15

22

34

50

100

OEX Pulse Duration: (early model–without OEX on/off switch)

Switch Position

1 & 2

1

2 & 3

2

3 & 4

3

4

Time (Milliseconds)

7

10

15

22

34

51

100

Anti-Overlap Adjustment:

CBC-700-90:

0 - 100 ms

CBC-700-24:

0 - 50 ms

Switching Inputs:

Two optically isolated, 10-30 VDC
Min. and Max. current input 3.1 - 9.5mA
Maximum off-state leakage < 2 mA

Ambient Temperature:

0° to 140° F (-18° to + 60° C)

Auxiliary Supply:

12 VDC, 250 mA maximum

Enclosure:

Rated NEMA 13 with optional enclosure (P/N 6042-101-004 )

Reorder Information

Model

Part No.

CBC-700-24

6042-448-002

CBC-700-90

6042-448-003

CBC-700-90C

6042-448-013

Enclosure

6042-101-004

Note: CBC-700-90C has a right angle terminal strip and is conformally coated.

®

DIST. AUTORIZADO

MEX (55) 53 63 23 31
QRO (442) 1 95 72 60

MTY (81) 83 54 10 18
[email protected]

Summary of Contents for CBC-700-90

Page 1: ...nstructions P 272A 819 0527 CBC 700 Series Overexcitation Clutch Brake Controls An Altra Industrial Motion Company DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas indus...

Page 2: ...a momentary high voltage spike builds up electromagnetic flux very quickly in the clutch and or brake coil for quick engagement and superior accuracy The CBC 700 works on the capacitive discharge pri...

Page 3: ...2 3 4 All Open Time milliseconds 8 11 15 22 34 50 100 OEX Pulse Duration early model without OEX on off switch Switch Position 1 2 1 2 3 2 3 4 3 4 Time Milliseconds 7 10 15 22 34 51 100 Anti Overlap...

Page 4: ...nal contact closure for the start signal and a sensor to initiate braking 4 50 114 3 1 85 47 2 50 63 5 5 00 127 3 25 82 5 4 65 118 1 0 125R TYP 3 2 0 50 12 7 0 50 12 7 6 PLS 0 20 5 1 0 95 24 0 100 R T...

Page 5: ...Clutch OEX Switch Overlap Pot Brake CBC 700 24 CBC 700 24 Model Switches On SF PB 120 1 0 SF PB 170 1 0 SF PB 250 1 3 SF PB 400 2 10 SF 500 2 16 PC PB 500 2 3 10 SF 650 3 4 18 PB 650 2 16 SF 825 3 4...

Page 6: ...6 Warner Electric 800 234 3369 P 272A 819 0527 Template for Mounting CBC 700 Base Mount Wall Mount DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com...

Page 7: ...Improper AC line voltage Check line voltage and correct if necessary Improper magnet voltage Check magnet voltage rating and replace with correct magnet if necessary Symptom D Magnets do not appear t...

Page 8: ...llation operation or maintenance Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you Warner Electric LLC s obligation under this warr...

Reviews: