background image

WP-207-F – this electronic thermostat is mounted in 
a standard flush box. The thermostat is adjustable to 

the required temperature from +5/+40˚C. The red 
LED shows that the heat is ON. This thermostat with a 

remote sensor is recommended for the control of 
floor heating systems and is designed to meet the 

standard requirements for comfort, safety and energy 
saving when using electric radiant floor heating. 

 

 

Mounting of Floor Sensor 
 

The floor sensor should be placed in between two 
runs of heating wire. Make sure it is centred so as to 

achieve the best accuracy. Make sure the position of 
this sensor is in an area of the floor that will not be 

covered over with any items that will cause a heat 
build up which could result in the overall floor 

temperature being affected i.e. washing baskets, rugs 
etc.  

 
 

Placement of Thermostat and Floor Sensor 
 
The thermostat is to be mounted on a wall so that it 

is easily accessible. The floor sensor should not be 
influenced by any other heating sources (i.e. the 

sun). 
 

 
Operation Manual 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

Temperature Setting 
 

The thermostat has a scale range of +5/+40˚C. To 
assist the adjustment, the thermostat has a LED 

which will glow RED when the heating is ON. The 
thermostat should be set to the maximum 

temperature setting until the desired temperature of 
the room or floor is achieved. The control knob 

should then be turned back until the LED goes out. 
Fine adjustments can be made over the next few days 

to suit individual requirements.  

 

 

Max/Min Temperature Setting 
 

A locking mechanism is positioned behind the control 
knob to limit the amount of adjustment possible. By 

loosening the little screw C the scale range can be 
locked i.e. between 20˚C and 25˚C. The red ring 

indicates the maximum temperature and the green ring 
indicates the minimum temperature.  

 
 

Technical data 
 

Max Load: 3.6kW/16A 
Voltage: 230-240V AC 

Setting range: 5 - 40˚C 
Setback temperature: 5˚C 

Switching differential: ±0.5K 
Temperature: -5 -50˚C 

Protective housing: IP20 
Floor sensor: cable length is 3m rubber-thermoplastic 

Housing material: anti-flammable PC 
 

Designed, tested and approved to Australian and New 
Zealand standards  
AS/NZS 3100:2002  

AS/NZS 3133:2003 
 

Parkside Laboratories Test Report No. 13188-00 dated 
1

st

 November 2007. 

 

 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

           
1.

 

On/Off               

׀

– On  O – Off 

 

2.

 

Temperature     
setting  

5 ~ 40˚C 

 

3.

 

Indicator 
The light is        

red when     
heat is On 

3

Installation Instructions 
WP-207-F Electronic Thermostat

Reviews: