  Kit for use with the 4iE

Step 6 - Control in event of communications error

18

+

The Kit for use with the 4iE has been designed to still provide heating control should 

the communication between the 

Power Base

 and 

Boiler Receiver

 be interrupted. 

With the 

Power Base

 and 

Boiler Receiver

 paired and the thermostat calling for heat, the relay 

will be activated and the 

Boiler Receiver

 will show a constant green LED indication. If the 

communication between the 

Power Base

 and 

Boiler Receiver

 is lost, the green LED will remain 

on the 

Boiler Receiver

 for a period of up to 30 minutes.

 

If communication has not been restored after 30 minutes has expired, the 

Boiler Receiver

 will 

indicate a communications fault by displaying a red LED flashing quickly.

 

To activate the relay whilst communication has been lost, press the power button on the 

Boiler 

Receiver

 once. The LED indicator will change from a constant to quick flashing red.

 

To de-activate the relay whilst communication has been lost, press the power button on the 

Boiler Receiver

 once. The LED indicator with change from constant red to flashing quickly red.

 

Once communication has been restored, the LED indicator will change back to constant green 

providing the thermostat is calling for heat.

Summary of Contents for + Kit

Page 1: ...Kit Installation Guide ...

Page 2: ...Step 2 Install the Boiler Receiver Step 3 Mounting Step 4 Pairing the 4iE to the Boiler Receiver Step 5 LED Indications Step 6 Control in event of communication error Step 7 Address setting Troubleshooting Technical Specifications 3 5 7 12 15 17 18 19 22 23 ...

Page 3: ...Kit for use with the 4iE Components Power Base Stand Boiler Receiver Power Adapter with 1m USB Cable 3 ...

Page 4: ...Kit Step 1 Download the MyHeating App ...

Page 5: ...one so already download the MyHeating app to your tablet or smartphone Registration After the app has been successfully downloaded you will need to set up your MyWarmup account The 4iE Device can be registered via the app or by visiting my warmup com Kit for use with the 4iE Step 1 Download the MyHeating App 5 ...

Page 6: ...Kit Step 2 Install the Boiler Receiver ...

Page 7: ...ified electrician It requires a permanent 230V supply The Boiler Receiver should be connected to the central heating fused spur or circuit breaker in accordance with current wiring regulations such that there is a single point of isolation for all interconnected devices Ensure that multi stranded wires are fully inserted into the terminals and secured tightly Any loose strands should be trimmed as...

Page 8: ...cts such as the boiler hot water cylinder or radiators should be at least 300mm away from the Boiler Receiver and not directly between it and the 4iE Loosen both screws at the bottom of the Boiler Receiver and remove the backplate Fix the backplate to the wall using fixing screws provided Make sure to avoid cables or pipes which may be buried in the wall 8 1 2 ...

Page 9: ...Kit for use with the 4iE Step 2 Install the Boiler Receiver Electrician Required Wiring Diagrams 9 1 2 3 4 3 ...

Page 10: ...an Required After the Boiler Receiver has been wired correctly reattach the front panel to the back plate and tighten both screws to secure Restore power to the boiler The LED on the Boiler Receiver will flash RED which means it has to be paired to the Power Base 4 10 4 ...

Page 11: ...Kit Step 3 Assembly ...

Page 12: ... Thread the power cable through the Stand and connect to the Power Base from your Kit Clip the Power Base onto the Stand Connect the plug to a wall socket For optimal performance the thermostat should be located in an area with good ventilation It should not be beside a drafty window door in direct sunlight or above another heat generating device e g radiator or TV 12 For Stand Mount ...

Page 13: ...all socket Attach the Power Base from your Kit to the wall using the fixing screws provided Connect the plug to the wall socket For optimal performance the thermostat should be located in an area with good ventilation It should not be beside a drafty window door in direct sunlight or above another heat generating device e g radiator or TV 13 For Wall Mount 1 2 NOTE For detailed instructions see on...

Page 14: ...Kit Setup ...

Page 15: ...own above on the Power Base to begin pairing 2 Power button LED Pairing Button 3 Attach the 4iE front face to the Power Base and tighten both closing screws Before pairing please make sure the Power Base and Boiler Receiver are powered The LED on the Boiler Receiver will flash in RED slowly NOTE If the devices have been paired before hold the Power button on the Boiler Receiver for 6 seconds and t...

Page 16: ...ase the air temperature by setting a temporary override Once the 4iE has powered up connect to your WiFi Network The heating indicator will appear on the 4iE the light on the Boiler Receiver will turn solid GREEN and your heat system should now activate override Wi Fi target Warmup until back back accept accept 21 0 C 15min 4 5 6 ...

Page 17: ...tep 5 LED Indications 17 LED Colour LED Status Meaning N A Not lit Paired Green Lit constantly Relay on Red Flashing slowly Not paired Red Flashing quickly Relay off Red Lit constantly Communication Lost Relay on LED LED Status ...

Page 18: ...ain on the Boiler Receiver for a period of up to 30 minutes If communication has not been restored after 30 minutes has expired the Boiler Receiver will indicate a communications fault by displaying a red LED flashing quickly To activate the relay whilst communication has been lost press the power button on the Boiler Receiver once The LED indicator will change from a constant to quick flashing re...

Page 19: ...hen using multiple Kit s each Power Base should be set to a unique address to prevent interference Use the dip switches on the Power Base to select the unique address 1 Represents ON up and 0 represents OFF down Dip Switches Address 31 Address 61 Address 53 Address 62 ...

Page 20: ...Kit for use with the 4iE Step 7 Address setting Address Set up 20 ...

Page 21: ...Kit Troubleshooting ...

Page 22: ...ase and using a device such as a paper clip press the pairing button as shown on page 15 The light on the Boiler Receiver will flash GREEN twice to indicate a successful connection Note You can manually override the system should the wireless connection fail by pressing the power button on the Boiler Receiver as shown on page 17 1 Check that the display standby brightness is not on the lowest sett...

Page 23: ...tions Dimensions Assembled with 4iE face 120 x 121 4 x 63 3mm Power Supply 5V DC 300mA IP Rating IP30 Operational Temperature Range 0 C 50 C Operational Humidity Range 95 RH Power Base Boiler Receiver RF Range Open Air Max 100m Communication Band 868 MHz Radio Frequency Standards EN301 489 1 V2 2 0 EN301 489 3 V2 1 1 EN300 220 1 V3 1 1 EN300 220 2 V3 1 1 EN 62479 2010 EN60950 1 2006 A2 2013 Wirele...

Page 24: ...ation or damage which occurred while the product was in the possession of a consumer Warmup s sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILU...