Step 6 - Control in event of communications error
18
+
The Kit for use with the 4iE has been designed to still provide heating control should
the communication between the
Power Base
and
Boiler Receiver
be interrupted.
With the
Power Base
and
Boiler Receiver
paired and the thermostat calling for heat, the relay
will be activated and the
Boiler Receiver
will show a constant green LED indication. If the
communication between the
Power Base
and
Boiler Receiver
is lost, the green LED will remain
on the
Boiler Receiver
for a period of up to 30 minutes.
If communication has not been restored after 30 minutes has expired, the
Boiler Receiver
will
indicate a communications fault by displaying a red LED flashing quickly.
To activate the relay whilst communication has been lost, press the power button on the
Boiler
Receiver
once. The LED indicator will change from a constant to quick flashing red.
To de-activate the relay whilst communication has been lost, press the power button on the
Boiler Receiver
once. The LED indicator with change from constant red to flashing quickly red.
Once communication has been restored, the LED indicator will change back to constant green
providing the thermostat is calling for heat.