INSTALLATION AND USAGE INSTRUCTION FOR 

THE ELECTRICIAN

 IMPORTANT NOTES:

•  Installation and service work must be carried out by a 

licensed professional or a qualified person. Verify that the 

electrical installation complies with the applicable local 

codes. The responsibility of the manufacturer is limited to 

the supply of the device.

•  The devices are designed for wall mounting (vertical or 

horizontal)  

•  Wall mounting of the glass radiators corresponds IP24 

Protection.

•  When installing the unit in a bathroom, follow local 

building  and electric code regulations.

•  Specified minimum distances must be respected.

INSTALLATION AND MINIMUM DISTANCES:

LAVA® glass heaters may be mounted horizontally or 

vertically on the wall. They must be positioned so that 

flammable items can not be ignited. Ensure that the 

required minimum distances, particularly to flammable 

objects like curtains, and upholstered furniture are correct. 

Please make sure that the glass radiator can radiate freely 

into open space. (See Fig. 2) 

ATTENTION: Don’t lean items against the glass or lean the 

radiator against other objects.

ASSEMBLY OF THE RADIATOR:
Please verify that no shipping or handling damage occured 

before installing the power cable to the radiator.

 

WALL MOUNTING:

The mounting brackets (supplied) have 3 groups of 2 holes 

spaced at 8” on center.  This spacing allows the installer 

flexibility when choosing a mounting location.  Please note 

the required minimum clearance distances from flammable 

materials (SEE Fig 2) when choosing your mounting 

location.  Ideally, if the studs in the room are 16” on center, 

this bracket will allow the unit to be attached to at least one 

stud and optimally 2 studs.  This bracket design also allows 

for the Lava to be mounted horizontally or vertically.

At this time, gather any needed items including a pencil, 

screw driver, screws, washers, hammer, tape measure, 

stud finder, wall anchors, and an assistant.  Verify correct 

number of supplied parts are present.

Choose a location desired for mounting.  Choose an area in 

compliance with local building and electrical codes.  

Use a stud finder to locate the studs present in the area.  If 

possible, choose a location where 4 screws on each bracket 

will land in studs.  If this is not possible, we suggest at 

least 2 of the screws on each bracket land in a stud.  Use 

Heavy-duty anchors rated to 50 lbs. for this application.  If 

mounting into concrete or other materials, use appropriate 

anchors suitable for that application.  We require using 

at least 4 (six is even better!) screws in each mounting 

bracket.  PLEASE VERIFY ACCESS TO ELECTRICAL BOX IS 

NOT BLOCKED BY INSTALLED MOUNTING BRACKET.

Use a level and a pencil to mark the location of the first 

bracket on the wall.  Using the bracket, mark the hole 

locations.  Drill and install the appropriate screws and/or 

anchors.  We recommend Cobra, TripleGrip #8, p/n:  178S 

(available at Home Depot) or similar type anchors.  We 

recommend using a #8 screw with washer (if needed), 

minimum, for mounting the mounting brackets.

Make corresponding marks 17 9/16” below the installed 

bracket for the lower bracket.  ALWAYS INSTALL 2 

BRACKETS per LAVA unit!  Follow above instructions for 

this bracket.  

Once the brackets are installed on the wall, install the 4, M8 

x 16 hex mounting bolts loosely (at least 3 revolutions) into 

the Lava.  

With the assistance of a helper, lift the Lava and make 

your electrical connections.  Place the mounted bolts into 

the slots of the mounting brackets.  If the unit is placed 

satisfactorily, use an open-ended wrench to fully snug the 

bolts, securing the Lava to the mounting products.

Installation and Usage Instruction | LAVA® Design Glass Radiator

Fig. 2: Minimum mounting distances

4

11.8” / 300mm  

7.8” / 200mm  

11.8” / 300mm  

11.8” / 300mm  

 18.9”/ 48cm

 18.9”/ 48cm

 13.8”/ 35cm

 29.5”/ 74.9cm

45.2”/ 114.8cm

57”/ 144.7cm

 18.9”/ 48cm

 18.9”/ 48cm

LAVA 250

LAVA 500

LAVA 750

LAVA 1000

Summary of Contents for LAVA Series

Page 1: ...LAVA Design Glass Radiator By WarmlyYours Installation Manual Read all instructions before installing or using this heater...

Page 2: ...the device The heater must not be placed or mounted directly below a wall socket WARNING Covering the glass surface causes overheating danger May cause damage to the heating element WARNING The glass...

Page 3: ...M8 x 16 G 8 x Anchors After attaching hardware do not tighten completely Only tighten hardware when unit is assured to mount by test fitting unit Electrical and electronic equipment frequently contain...

Page 4: ...ot pictured 4 x wall anchor screw not pictured F 1 x wall protection plate K 8 x Anchors After attaching hardware do not tighten completely Only tighten hardware when unit is assured to mount by test...

Page 5: ...At this time gather any needed items including a pencil screw driver screws washers hammer tape measure stud finder wall anchors and an assistant Verify correct number of supplied parts are present C...

Page 6: ...40 6cm 6cm 17 5 44 4cm 15 9 40 6cm 3 7 62cm 3 7 62cm 50 15 9 40 6cm 6cm 50 17 6 44 8 cm 17 5 44 4 cm LAVA 500 750 1000 LAVA 500 750 1000 Graphic LAVA Glass radiators 250W 500W 750W 1000W Hole drilling...

Page 7: ...n LAVA Design Glass Radiator 6 Stud Stud OR Stud Mounting Bracket Mounting Bracket Drywall anchors and screws must be used in the remaining 4 holes Drywall anchors and screws must be used in the remai...

Page 8: ...ATTENTION Verify minimum distances Use required mounting holes and anchors Fig 6 4x Fig 5 Fig 4 Fig 8 Fig 7 BACK Stud BACK Stud BACK Stud BACK Stud BACK Stud 7 MOUNTING BRACKET ASSEMBLY 250W...

Page 9: ...d with the supplied connector to a junction box supplying the AC power supply If a longer cable is required it can be replaced by longer one 18 AWG or Larger HEATING The heater is controlled by the ex...

Page 10: ...e AC power supply If a longer cable is required it can be replaced by longer one 18 AWG or Larger HEATING The heater is controlled by the externally mounted thermostat GROUNDING The heater is for use...

Page 11: ...ned safety glass ESG This glass is much more durable than conventional glass and is designed for significantly higher impact forces However you should avoid excessive use In case of damage ESG shatter...

Page 12: ...ot to expectations Is the distance between glass radiation heater and person too great Is the glass radiation heater undersized for the space Are there objects between the person and the glass radiati...

Page 13: ...process and tested before shipment to exacting quality control standards If you follow these installation and operating instructions your LAVA glass radiator will provide many years of trouble free en...

Reviews: