9
ELECTRICAL CONNECTION FOR LED KIT
The heater is designed for permanent connection to a
suitable room thermostat. Please refer to the instructions
of the room thermostat.
ATTENTION
:
If the power cord of the unit is damaged, it
must be replaced immediately.
Optional: If you decide to purchase the optional LED kit,
you may want to install a recessed duplex outlet behind the
unit. One outlet in the duplex outlet will be controlled by
the thermostat, and the other will be controlled by a wall
switch. If your LAVA™ came with a plug, it will plug into
that outlet. If your LAVA™ did not come with a plug, one
can be easily installed. See instructions included in the
plug box.
The device is connected with the supplied connector to
a junction box supplying the AC power supply. If a longer
cable is required, it can be replaced by longer one, 18 AWG
or Larger.
HEATING
The heater is controlled by the externally mounted
thermostat.
GROUNDING
The heater is for use with 120 volts. The green-yellow
grounding of the cord must be connected to a permanent
ground inside the junction box.
Fix mounted thermostats should be mounted next to the
heated room’s entry door at 4’ or 1.3m height from floors.
An alternate location is on an interior wall, not subject to
direct sunlight. The thermostat should not be installed
within 3 feet of the LAVA. Power the thermostat with a
GFCI Protected Circuit.
2” x 4” ELECTRICAL BOX
LAVA Radiant Panel
Plug
Install Pass & Seymor ID: PS5965OCC15
Home Depot SKU: 144940 or similar
LED Power Supply
Leviton
Recessed Box
Leviton #689
Follow wiring
instructions included
in receptical box
POWER
SWITCH
15 amp GFCI
circuit breakers
Hot
Black
Hot
Black
Neutral
White
Neutral
White
Ground
THERMOSTAT
ELECTRICAL BREAKER PANEL
Load
Line
OPTIONAL LED KIT WIRING
10