PROCEDURE FOR THE TEST AND COMISSIONING OF YOUR DECORATIVE FIRE.
Ensure Gas Supply and the Power Supply (caution 240V) to the Unit.
•
Refer to Data Plate on this Specification for settings. The Data Plate is attached to the under carriage of
the Burner .
•
Loosen the Jet Test point and attach manometer (Digital is preferred). The Test Point is on the Right Hand
Side of the Gas Burner , as Shown Below .
•
Light Appliance, adjust to High Flame setting and check pressure, adjust to Low Flame and check pressure.
NOTE : If setting the Pressure is required it is to be carried out by a Certified Gas Fitter.
•
If adjustments are necessary, remove the cap . The Pressure Adjustment Screw and Nut are on the Front
Side of the Gas Control Valve (shown in Diagram
B
in this specification) and are
Factory
set.
High Pressure Setting
: Set the Burner to High with the switch. Screw in
Nut A
to Increase the Outlet Pressure
then screw Nut A out to Decrease the Pressure to the desired settings . Use 10mm spanner.
Low Pressure Setting:
Set the Burner to Low with the switch
-
See Wiring Diagram) and, keep Nut A stationary .
Use a screwdriver to screw in
Screw B
to Increase the Pressure and Screw it Out to Decrease the Pressure .
Carefully replace the Modulator Plastic Cap .
WARNING:
To ensure the Correct Operation of the Hi/Low burner it is necessary that the Plastic Cap is returned
to its original location .