29 March 2021
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
15
DIAGRAM B ( SHOWING CONTROL VALVE WITH TEST POINTS AND ADJUSTING SCREW )
•
After checking the pressure, turn the unit off, remove Manometer from the Test Point and Tighten the Test Point
Screw. Ensure to check for gas leaks.
•
Ensure Power is Off & Reconnect Modulator Harness Connection in the Main Harness. See Diagram B Above .
•
Turn the Appliance On and Off a few times to check ignition.
•
When you are satisfied that the Appliance is working correctly , fit the Front Panel Assembly back to the Gas
Burner.
•
NOTE : Ensure you peel the Protective Plastic Coating from any Stainless Steel components if fitted.
•
All Burner Aerations are Factory Preset and cannot be adjusted.
•
If you are unable to get the unit to operate correctly, refer to troubleshooting before contacting your Local Service
Contact as listed.
•
It may take approximately 2 hours of operation for the coals/Logs or river rocks to achieve their full flame pattern
and glow.
•
During the Initial Burning in period, some smoke and smell may be experienced , the appliance should be run on
the high position in a well ventilated room until these dissipate .
Test Point Inlet
Hi LOW Harness Connections
Test Point Outlet
1/2”
BSPT Gas Outlet
SIT 843 Control Valve
Nut A
High setting adjustment
screw
Screw B
Low setting adjustment screw
ADJUSTMENT OF THE PILOT—
3
FLAME (BOTH SG & EG) (Only to be Adjusted by Gasfitter)
Note:
When the Base screw is removed, gas will leak from the out let, ensure that the pilot is not ad-
justed or the screw is removed when the fire is burning.
•
Adjustment of Pilot
-
3 Flame : Unscrew Base Screw as shown in Diagram 2 .
•
Insert a Screw Driver as shown in Diagram 3 and adjust the Adjustment Screw up inside the 3
Flame Pilot to adjust the Flame Height .
•
The Flame must always be passing over the Electrodes &/or File Tube on either side .
•
Replace the Base screw and check for leaks.
Note: to Gas Fitters
The 3 flame pilot may need adjust-
ment after a period of running time
on set up as the increase in heat in
the fire will induce a higher draft in
the fire, and may pull in flame away
from the File Tube causing the fire to
shut down.
3 Flame Pilot in
Correct Operation of
3 Flame Pilot
3
2
1