29 March 2021
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
8
ADJUSTMENT OF HI—LOW PRESSURE (SG ONLY) (Only to be Adjusted by Gasfitter)
Note* Control Valves are Factory Set but may require adjustment onsite .
Turn Appliance Off & Remove Front Plastic Cover on Igniter , Pull Cover to Slide off .
Unscrew Test Nipple on the Burner Manifold & fit the Test Gauge Securely
-
See Diagram
* To Set the High : Light the Burner & turn to High
-
Then Adjust the High Screw to the Desired Pressure . See Spec
’
s
* To Set the Low : Light the Burner & turn to Low
-
Then Adjust the Low Screw to the Desired Pressure . See Spec
’
s
Extinguish Appliance, remove Test Equipment and Secure Test Nipple .
* Check Valve & Burner for Correct Operation & check Fire for Gas Leaks .
Adjustment of High & Low Settings Must be Carried out by a Certified Gas Fitter Only
.
ADJUSTMENT OF THE PILOT—
3
FLAME (BOTH SG & EG) (Only to be Adjusted by Gasfitter)
Note:
When the Base screw is removed, gas will leak from the out let, ensure that the pilot is not adjusted
or the screw is removed when the fire is burning.
•
Adjustment of Pilot
-
3 Flame : Unscrew Base Screw as shown in Diagram 2 .
•
Insert a Screw Driver as shown in Diagram 3 and adjust the Adjustment Screw up inside the 3
Flame Pilot to adjust the Flame Height .
•
The Flame must always be passing over the Electrodes &/or File Tube on either side .
•
Replace the Base screw and check for leaks.
3 Flame Pilot in
Assembled State
Correct Operation of
3 Flame Pilot
3
2
Note: to Gas Fitters
The 3 flame pilot may need adjustment
after a period of running time on set up
as the increase in heat in the fire will
induce a higher draft in the fire, and
may pull in flame away from the File
Tube causing the fire to shut down.
Gas
Test
Nipple
for SG
Burn-
1