For electronic ignition models requiring power supply — a 

qualifi ed, licensed electrician must install power supply. 

The unit may be hardwired or an outdoor NEMA rated 

GFCI Receptacle outlet can be installed on the interior of 

the enclosure above grade to supply power to system. 

Minimum ventilation requirement: Incorporate 1 vent 

on at least two opposing sides (2 vents total) at a 

minimum size of 18 sq. inches each (Example: 3"x 6" or 

larger). Installation of the vents in the mid to lower area 

of the enclosure is recommended. Ventilation allows for 

heat and/or residual fuel to escape. Failure to properly 

vent enclosure may result in the appliance overheating 

or explosion. Overheating could lead to heat damage 

to internal components. Some enclosures may require 

more ventilation based on material, size, and extended 

use. Always consult with local municipality regarding 

any code requirements.

Ready-to-Finish 

Kits come with Fire 

Pit Vent Kit (FPVK). 

Vents do not come 

pre-installed on 

Ready-to-Finish Kit 

as placement and 

installation depends 

on veneer. Vents 

to be installed by 

contractor on site.

The interior space of the enclosure cannot be fi lled with 

any material (gravel, crushed rock, concrete, etc.). 
The appliance assembly should be recessed 4"- 6" from 

CONSTRUCTION OF 

ENCLOSURE

WARNING:

All appliances must have a gas shutoff 

on the outside of the fi re pit to allow for 

emergency shut off and maintenance. 

WARNING:

For electronic ignition models, there must 

be an electrical shutoff (wall switch or 

breaker) on the exterior of the appliance 

or on adjacent structure to allow for 

emergency shutdown and maintenance. 

Verify correct power supply. 

If located on the vessel, key valve should be mounted 

below the plate and through the side wall of the vessel. Key 

valves may be mounted remotely or on adjacent surfaces.
Always use proper materials and construction for gas sup-

ply, power and enclosure. Materials must be non-combusti-

ble in both initial installations as well as over time. 

the top of the enclosure to protect fl ame from excessive 

wind. Some conditions may require deeper recession.   
It is the responsibility of the installer to provide proper in-

stallation to allow for easy accessibility for service and/or 

repairs. Installer must not build capstone inner ledge over 

outer lip of plates or pans (unless access panel door or 

alternate access is incorporated). Building capstone inner 

ledge over outer edge of plates or pans will impede ac-

cess to system and result in the need to crack or remove 

capstones to gain access. Warming Trends is not responsi-

ble for damage to enclosure for any reason whatsoever. 

WARNING: These instructions do not 

apply to vessels or appliances with self 

contained propane gas supply systems.  

Appliances or vessels with self contained 

propane gas supply systems have 

additional specifi c requirements which 

must be identifi ed and met by the vessel 

installer or manufacturer.  Please consult 

with a qualifi ed installer for guidance and 

required installation procedures.

Summary of Contents for CFBL170 NG

Page 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Page 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Page 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Page 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Page 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Page 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Page 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Page 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Page 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Page 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Page 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Page 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Page 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Page 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Page 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Page 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Page 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Page 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Page 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Page 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Page 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Page 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Page 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Page 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Page 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Page 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...

Reviews: