MATCH LIT SYSTEM INSTALLTION 249K BTU SYSTEMS AND BELOW CONTINUED
4. Connect Whistle-Free Flex Line
(FK1) Connect the Whistle-Free Flex
Line to the Flared Fitting previously
attached to the coupling on the
bottom of the aluminum plate.
6. Connect Flex Line with Key Valve
(FK1) Connect the Whistle-Free Flex
Line to the Flared Fitting that is now
connected to the Key Valve.
Connect Escutcheon Plate to Key
Valve through vessel wall. Tighten.
Flared Fitting
Coupling
Flared Fitting
Whistle-Free Flex Line
Key
WALL
GAS LINE IN
FK1 SHOWN
Escutcheon
Plate
Plate
Coupling
Flared Fitting
Whistle-Free
Flex Line
5. Locate 2nd Flared Fitting and Connect to Key Valve
(FK1) Locate the second Flared Fitting removed in Step
2 and connect into the Key Valve, placing the non-
flared end into the key valve. Tighten.
STEP 5
Key Valve
Flared Fitting
Apply thread
sealant here
Key Valve