Warming Trends CFBL170 NG Owner'S Manual And Instruction Manual Download Page 24

www.Warming-Trends.com  |  303 346 2224  |  [email protected]

24

at no cost for the first year. In the event a system fails after the first year and 

within two years of date of purchase, the cost for a replacement system is 

at a discount rate of 50% of the current listed price. This warranty does not 

cover labor costs. 

• P24VIK Systems purchased AFTER April 15, 2018 are fully warranted 

for three (3) years from date of purchase. In the event a system must be 

replaced due to a defect/malfunction of the system, Warming Trends will 

repair or replace the system at no cost for the first three years.  This warran-

ty does not cover labor costs.

Commercial Installations:

• 24VIK and 3VIK systems are fully warranted for twelve months from date of 

purchase. In the event a system must be replaced due to a defect/malfunc-

tion of the system, Warming Trends will repair or replace the system at no 

cost. This warranty does not cover labor costs. 

• P24VIK Systems are fully warranted for one (1) year from date of purchase. 

In the event a system must be replaced due to a defect/malfunction of the 

system, Warming Trends will repair or replace the system at no cost for 

12 months from the date of purchase. This warranty does not cover labor 

costs.

Problems in the functioning of the systems due to gas plumbing or electrical 

installed by others are not covered by any warranty offered by Warming 

Trends.
No dealer, distributor, or other person has the authority to represent or 

warrant a Warming Trends™ product beyond the terms contained within this 

warranty, and Warming Trends assumes no liability for such warranty repre-

sentations. Any questions concerning this warranty should be directed to the 

Warming Trends™ corporate office.

Return Policy of Warranty Product 

Any Warming Trends™ product deemed by Warming Trends™ as defective 

and covered by the warranty may be returned to Warming Trends™ for 

assessment to determine if repair or replacement is necessary. In order to 

return a product, you must have a Return Merchandise Authorization number 

(RMA#). Please contact a Warming Trends™ representative at the corporate 

office to obtain an RMA#. All returned merchandise must have the RMA# 

clearly printed on the outside of the package.  Return shipping costs are the 

purchaser’s responsibility. Warming Trends™ is not responsible for product 

damaged or lost in transit. It is recommended that return items are shipped 

via a delivery service that can be tracked and/or insured to confirm receipt. 

WARRANTY

Effective June 15, 2020
FULL LIFETIME WARRANTY FOR WARMING TRENDS® BURNERS
WARMING TRENDS warrants that each WARMING TRENDS® Crossfire® 

and other jetted-flame-brass-burners (each as “Burner”) is free from defects 

in materials and workmanship and conforms to its specifications, which are 

available upon request.
The warranty period for a Burner is lifetime warranty beginning on the 

date of purchase (“Warranty Period”). This Warranty is transferable, but we 

reserve the right to require proof of ownership for any transferred burners 

including proof that the Burner was not acquired through improper means 

or unauthorized re-sellers. During the Warranty Period, WARMING TRENDS 

provides repair and exchange services for the Burners, without charge.  If 

a Burner does not function as warranted during the Warranty Period and, 

after a reasonable number of attempts, WARMING TRENDS is unable to 

either 1) make it do so or 2) replace it with one that is at least functionally 

equivalent, you may return it to WARMING TRENDS and your money will be 

refunded.
The warranty stated above will not apply to the extent that there has been 

misuse or use contrary to specifications or the appropriate user or operat-

ing manual, installation defect, accident, modification, unsuitable physical 

or operating environment, operation in other than the specified operating 

environment (e.g., outdoor burners should only be used outdoors) improp-

er maintenance by you, or failure caused by a product for which WARMING 

TRENDS is not responsible.  With respect to Burners, the warranty is voided 

by removal or alteration of any identification labels or marks on any Burner 

or part.
THESE WARRANTIES ARE YOUR EXCLUSIVE WARRANTIES AND REPLACE 

ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, 

INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR 

CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE.
ITEMS NOT COVERED BY WARRANTY 

Other than as expressly stated above, WARMING TRENDS does not warrant 

uninterrupted or error-free operation of any Burner or that WARMING 

TRENDS will correct all defects. 

Warming Trends does not warranty any services related to our Burners, 

including installation, unless we provided those services to you.  You may 

have warranty rights from the service provider, but we make no represen-

tations or warranties express or implied regarding any third party service 

provider. 

This warranty also does not apply to any fire logs (including the FireStorm® 

Steel Log) or any of the electronics used in connection with our Burners, 

which may be covered by separate warranties with different terms.
YOUR RIGHTS UNDER STATE LAW 

This Warranty gives you specific legal rights, and you may also have other 

rights which vary from state to state.  You may find this information from the 

Federal Trade Commission helpful in understanding your rights, but we 

recommend you speak to your attorney regarding your specific situation 

and the laws in your state or jurisdiction.  https://www.consumer.ftc.gov/

articles/0252-warranties
IGNITION SYSTEMS WARRANTY  

ALL BURNERS AND ELECTRONICS MUST BE COVERED WHEN NOT IN 

USE OR WARRANTY IS NULL AND VOID

Push Button Ignition Systems: 

There is no warranty offered on any push 

button ignition system.

Electronic Ignition Systems:

 

Residential Installations:

• 24VIK and 3VIK systems are fully warranted for one (1) year with a limited 

warranty for two (2) years from date of purchase. In the event a system 

must be replaced due to a defect/malfunction of the system, Warming 

Trends will repair or replace the system at no cost for the first year. In the 

event a system fails after the first year from date of purchase and within 

two years from date of purchase, Warming Trends will repair or replace 

the system for a cost of 50% of the current list price. This warranty does not 

cover labor costs. 

• P24VIK systems purchased ON OR BEFORE April 15, 2018 are fully war-

ranted for one (1) year with a limited warranty for two (2) years from date 

of purchase. In the event a system must be replaced due to a defect/mal-

function of the system, Warming Trends will repair or replace the system 

Summary of Contents for CFBL170 NG

Page 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Page 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Page 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Page 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Page 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Page 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Page 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Page 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Page 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Page 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Page 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Page 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Page 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Page 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Page 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Page 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Page 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Page 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Page 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Page 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Page 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Page 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Page 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Page 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Page 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Page 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...

Reviews: