Plume Displacement Kits Ø60 mm
Product Name
Specification
Product Code
Plume Displacement
Terminal Kit
With 1 m Extension and
Two Brackets
153.11.660.6000 31
Plume Displacement
Kit Bend
900
153.11.660.6000 32
Plume Displacement
Kit Bend
450
153.11.660.6000 33
Plume Terminal
153.11.660.6000 34
Clamp Pack
153.11.660.6000 35
Plume Displacement Kit Extension
and Brackets
1000 mm
153.11.660.6000 36
Figure 46
Installation Position of Plume Displacement Set to
Window or Door
2.4.7. Recommendations of Plume Kit
Installation
NOTE: Due to the nature of the boiler a plume
of water vapour will be discharged from the
flue. This should be taken into account when
siting the flue terminal.
1. The following guidelines indicate the
general requirements for siting balanced
flue terminals. For GB recommendations
are given in BS 5440 Pt 1. For IE
recommendations are given in the current
edition of I.S. 813 “Domestic Gas
Installations”.
2. If the terminal discharges onto a pathway
or passageway, check that combustion
products will not cause a nuisance and
that the terminal will not obstruct the
passageway.
3. If a terminal is less than 2 metres above
a balcony, above ground or above a flat
roof to which people have access, then a
suitable terminal guard must be provided.
4. *Reduction to the boundary is possible
down to 25 mm but the Plume
Displacement Kit Bend (45°) (part no.
153.11.660.6000 33) must be fitted.
IMPORTANT:
• Under car ports we recommend the use of
the plume displacement kit.
• The terminal position must ensure the safe
and nuisance - free dispersal of combustion
products.
IMPORTANT:
If fitting a Plume Displacement Flue Kit, the
air inlet must be a minimum of 150mm from
any opening windows or doors)
Opening Window
or Door
150 mm
MIN.
Plume
Displacement Kit
Air Inlet