8
warmhaus.co.uk
2.1.2. On/Off/Stand-by Positions
The boiler panel does not have
ON/OFF
button. The boiler must be turned
on/off by using the V circuit breaker connected to the boiler circuit.
The temperature value displayed on the combi screen has a ± 3°C tolerance
depending on environmental conditions not arising from the combi.
RESET: It is used for resetting the failure (if temporary) re-starting the
boiler
MODE:
Used for Winter/Summer/OFF mode adjustment.
Operating modes and related notifications:
OPERATING MODES EXPLANATIONS:
•
OFF
•
WINTER
►
Radiator tempe °C + tap + radiator is displayed.
•
SUMMER
►
Radiator tempe °C + tap is displayed.
•
CH ON
►
Radiator Tempe °C + tap + flashing radiator (symbol)
is displayed.
•
DHW ON
►
DHW tempe °C + flashing tap (symbol) is displayed.
•
CH FROST PROTECTION
►
Radiator temperature
• °C + flashing radiator (symbol) + when boiler is ignited flame (symbol)
is displayed.
•
DHW FROST PROTECTION
►
CH tempe °C flashing radiator
and tap (symbol) + when boiler ignited flame (symbol)
•
CH/DHW SETTING CHANGE
►
CH adjustment change will be activated
when radiator symbol rapidly flashes. DHW adjustment change will be
activated when tap symbol rapidly flashes.
• Service technician function ra tap displayed. (Only for authorized
service, wait for the function to end without pressing any button or rotating
the button in such case!)
CH :
Central Heating
DHW :
Domestic Hot Water
When the combi is started for the first time,
screen displays nG letter and then a number
(for instance 24) indicating kW power of the
device
and screenlight is closed. Now, combi is at
STANDBY position. The temperature value
when electricity is supplied to the device
is the temperature value of water in the
installation.
Then, OFF letter is displayed,
OFF
OFF
2.1.3. Operation in Winter Mode
In winter mode, boiler operates both for heating the environment and
providing Domestic Hot Water. Radiator (CH) temperature adjustment is
made with (3) and (4) numbered buttons in Figure 1 Domestic Hot Water
temperature adjustment is made with (6) and (7) numbered buttons and
this temperature is indicated with (9) numbered indicator for Radiator (CH)
and with (11) numbered indicator for Domestic Hot Water.
Radiator temperature is adjusted with button
(3) and Domestic Hot Water temperature
adjustment is made with button(4) and this
temperature is displayed by indicator (7) on
the screen.
In order to shuton the combi, hold
MODE
button, whereas a circle starts on the screen,
release the button when circle
is
completed.
In such case, combi initially gets in the
Radiator position, its symbol flashes at left
top corner of screen and existing radiator
installation temperature is displayed on the
screen and then screen light turns off. At
that position, you can adjust the temperature
between 25 – 80 °C with the Radiator
temperature adjustment button (3).
You can increase (14) and decrease (15) the
temperature with temperature adjustment
buttons (see.Figure 48) between 25 – 80
°C, screen lights when buttons are pressed
and °C symbol flashes besides the radiator
temperature value.