ErP DATA  (According to EU regulation No 813/2013 and 814/2013)

Ewa-2525C 

Ewa-2525C

Ewa-2530C

Ewa-2530C

2525C

2525C

2530C

2530C

Water heating - Declared load profile

L

XL

L

XL

Reated Heat Output

Prated

kW

24

24

24

24

Useful heat output at rated heat output and high 

temperature regime (2)

P

4

kW

23.7

23.7

23.7

23.7

Useful heat output at 30% of rated heat output and low 

temperature regime (1)

P

1

kW

4.16

4.16

4.16

4.16

Seasonal Space Heating Energy Efficiency

η

s

%

92

92

92

92

Useful efficiency at rated heat output and high temperature 

regime(2)

η

4

%

87.57

87.57

87.57

87.57

Useful efficiency at 30% of rated heat output and low 

temperature regime(1)

η

1

%

97.48

97.48

97.48

97.48

Auxiliary Electricity Consumption

Full load

elmax

kW

0.43

0.43

0.43

0.43

Part load

elmin

kW

0.11

0.11

0.11

0.11

Standby mode

P

SB

kW

0.005

0.005

0.005

0.005

Other Items

Standby heat loss

P

Stby

kW

0.057

0.057

0.057

0.057

Ignition burner power consumption

P

ign

kW

0.000

0.000

0.000

0.000

Space heating - annual energy consumption

Q

HE

GJ

42.14

42.14

42.14

42.14

Sound power level, indoors

L

WA

dB

52

52

52

52

Emissions of nitrogen oxides

NO

x

mg/kWh

20

20

20

20

Domestic Hot Water Parameters

Declared Load Profile

L

XL

L

XL

Daily electricity consumption

Q

elec

kWh

0.117

0.169

0.117

0.169

Annual electricity consumption*

AEC

kWh

26

37

26

37

Water Heating Energy Efficiency

h

wh

%

81

84

81

84

Daily fuel consumption

Q

fuel

kWh

14.809

23.152

14.809

23.152

Annual fuel consumption

AFC

GJ

11

18

11

18

Condensing boiler

-

Yes

Yes

Yes

Yes

Low temperature boiler

-

Yes

Yes

Yes

Yes

Combi Boilernation boiler

-

Yes

Yes

Yes

Yes

B1 Boiler

-

No

No

No

No

Room boiler with combi boilerned heat and power

-

No

No

No

No

Auxiliary boiler

-

No

No

No

No

Brand Name

Warmhaus

Manufacturer adress

Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş. 

Minareliçavuş OSB Mahallesi Selvi Cad. No:3 Nilufer/Bursa/Turkey

Warnings  

All spesific precautions for assembly, installation and maintanance are described in the operating and installation 

manual. Read and follow the operating and installation manual.

Read and follow the operating and installation manual regarding assembly, installation, maintenance, removal, 

recycling and/or disposal.

* for avarage climatic conditions

(1) Low temperature means for condensing boilers 30 

o

C, for low temperature boilers 37 

o

C and for other heaters 50 

o

C return temperature (at heater inlet).

(2) High temperature regime means 60 

o

C return temperature at heater inlet and 80 

o

C feed temperature at heater outlet.

As this is the property of Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş. It must not be passed on to any person not authorized by Warmhaus Isıtma ve Sogutma Sistemleri 

San. Tic. A.Ş or be copied or otherwise utilized by anybody without expressed written permission.

All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements 
in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale 
which are available on request.

Summary of Contents for EWA 2525C

Page 1: ...CONDENSING COMBI BOILERS USER MANUAL EWA 2525C EWA 2530C...

Page 2: ...ith limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safety or they have bee...

Page 3: ...of On Off Stand by and Summer Winter Modes 8 2 1 3 On Off Stand by Positions 8 2 1 4 Operation in Winter Mode 8 2 1 5 Operation in Summer Mode 9 2 1 6 Shutting off the Boiler 9 2 2 USE WITH ROOM THERM...

Page 4: ...le The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installation errors shall be performed as free of charge without claimi...

Page 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT S...

Page 6: ...ly at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make any intervention...

Page 7: ...klet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the b...

Page 8: ...the first time screen displays nG letter and then a number for instance 24 indicating kW power of the device and screenlight is closed Now combi is at STANDBY position The temperature value when elect...

Page 9: ...60 C with the Domestic Hot Water temperature adjustment button 4 Screen light will be open during adjustment tap symbol and Domestic Hot Water temperature value will flash You can adjust the hot tap...

Page 10: ...n Device installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room...

Page 11: ...r systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1 Ke...

Page 12: ...stion or electrode Condensate Syphon blocked Electronic board 1 Call for authorised service E 09 No water circulation in the system Boiler does not work E09 error code flashing on the screen Lack of w...

Page 13: ...mmunication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be r...

Page 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Ga...

Page 15: ...ectrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blocka...

Page 16: ...and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat l...

Page 17: ...oduct information listed elsewhere may result in different test conditions Only the data that is contained in this product information is applicable and valid Electricity Fuel HANDING OVER After compl...

Page 18: ...fuel consumption AFC GJ 11 18 11 18 Condensing boiler Yes Yes Yes Yes Low temperature boiler Yes Yes Yes Yes Combi Boilernation boiler Yes Yes Yes Yes B1 Boiler No No No No Room boiler with combi boil...

Page 19: ...19 warmhaus co uk...

Page 20: ...act Cadent s Plant Protection team Cadent provide first line support for our assets Gas Emergencies If you smell gas or have accidentally hit the NTS pipeline please call us urgently 0800 111 999 Elec...

Reviews: