VACCUM SWITCH
The STOVE has s vacuum switch located behind the left door, fastened to the base. If a low pressure
is created in the firebox by a leak, opening the front door, a blocked flue, or unsealed ash drawer, the
vacuum switch will sense it and cause the stove to go into a shutdown mode.
AUGER AND AUGER MOTOR
The 5 RPM auger motor turns the auger, lifting pellets up the auger tube. The pellets are then dropped
down a tube and into the firepot. The auger is controlled by the control board.
OVER TEMPERATURE SNAP SWITCH
This switch is installed on the bottom of hopper and shut off the stove if it senses excessive
temperatures(70 degrees). This snap switch can be changed by resetting programs in the chip!
CONVECTION BLOWER SNAP SWITCH
This switch is installed on the vent pipe and turns the convection blower on when the stove gets up to
temperature (35 degrees). Besides, switch off the stove when the temperature goes below 35degrees