8 The blower still works
after the stove is cool and
fuel feed stops.
The low temperature
switch (30
˚
C) is broken.
Change this switch.
9 no enough heat wind
Unqualified fuel
Blower speed is too high.
Heat exchange tubes are
dirty.
Use the standard specially pellet.
Use higher power
Clean the heat exchange tubes.
10. Showing "Pressure
Erro" on the display
Vent pipe is blocked
The door is opening
The are some leakages
Shut down the stove, check the
venting pipe
Close the door and unplugged then
restart
Check it and repair it.
Adjust the combustion fan's speed
up to offer more pressure in the
stove
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator’s electrical regulator may not be compatible with the stove’s
electronics. The higher the quality of the generator, the greater the chance that it is compatible
with the stove.