Wiring diagram
2009231 [Rev. 4 - en]/2015-12-08
Page 11 | 14
7
Wiring diagram
De-energise the product and lines before connecting and secure them against being switched on again.
7.1
On-site connection with terminals
On-site connection
On-site connection with terminal
Line (recommendation: H05RR-F 4 G
0.75 bk type WAREMA)
3
Not assigned
2
Phase L (black)
1
Neutral conductor (blue)
2
1
PE conductor (green-yellow)
7.2
Motor connection with terminals
Motor connection
Motor line with terminal
Motor line (H05RR-F 4 G 0.75 bk type
WAREMA)
3
Brown
2
Black
1
Blue
M
~
3
2
1
Green-yellow
8
Technical data
WMS-RP
8/17
WMS-RP
12/17
WMS-RP
20/17
WMS-RP
30/17
Rated torque
8 Nm
12 Nm
20 Nm
30 Nm
Output speed
17 rpm
Mains voltage
230 V/50 Hz
Current consumption
0.45 A
0.50 A
0.75 A
0.90 A
Power consumption
100 W
110 W
160 W
205 W
Degree of protection
IP 44
Safety class
I
Short-term operation (S2)
4 min.
Limit switch range
64 revolutions
Transmission frequency
2.40–2.48 GHz
Transmission power
< 10 dBm
INFO
Detailed technical data can be requested from WAREMA.