background image

DE

ES

FR

IT

EN

Page 1 of 1

HOW TO USE

© W&W Cycles AG, 2022-07-13, ID 232933, rev. 0.20, wwag.com

Samwel 12V Conversion Kits 
for 32E Generators

Item-

13-815

•  Note: Use grease on the oil seal. The armature 

must be pulled carefully into the bearing. Do not 
use force, do not hammer. If necessary, build 
yourself tools! 

•  Check air gap between armature and field coil 

cores: 0.8 mm on both sides. If the air gap is too 
small, re-tighten field coil screws. Here, too, a 
special tool like a pressing arbour can be useful. 

•  Mount brush carrier and connect field coils (see 

diagram). 

•  After correct connection of the coils, the relay 

terminal will serve as A terminal, the switch ter-
minal as F terminal (important for connection of 
the regulator). 

•  Replace bearing ID 12 mm in left side bearing 

carrier and complete generator assembly. As 
mentioned above, omit the carrier of the 3rd 
brush together with the brush. The generator 
must be polarized before installation or at least 
before connecting the regulator. 

Content: 

•  2 field coils 12 V, pre-wired 

•  1 armature 12 V 

•  1 bearing ID 15 mm 

•  1 bearing ID 12 mm 

•  1 oil seal ID 19 

•  1 gasket for brush carrier 

Assembly: 

•  Dismantle and clean the generator completely. 

(See manuals for details.) Check parts and buy 
damaged ones. 

•  Put 3rd brush (= regulating brush) aside. 

•  Mount the oil seal in the housing with the 

sealing lip facing towards the engine. Reuse 
circlip if possible. 

•  Mount 15 mm bearing in housing, pay attention 

to perpendicularity. 

•  Mount new 12 V field coils in the housing (see 

illustration). Ensure that the cables are laid 
correctly! 

•  Mount the armature in the housing.  

Wiring scheme

Relay = A

Switch = F

 Mounts in place of the regulating coil

 Mounts in place of the shunt coil

Reviews: