96
W&T
Security & Maintenanceh
password and the basic network parameters are configured.
Only after this step is access to the management interface of
the Microwall VPN protected by the password.
IP assignment
During initial commissioning, ensure that there is no unau-
thorized access to the Microwall until the password has been
assigned on the initial web page. A suitable measure is, for
example, to perform the commissioning via a point-to-point
connection with the configuring computer. Only then is the
Microwall connected to the actual target networks.
Password
Operational use of the Microwall without a password is not
possible. The password is the central protection against un-
authorized access to the configuration and management of
the Microwall. We recommend using a secure password with a
length of at least 15 characters, consisting of upper and lower
case letters, digits and special characters.
Registration for security-related information
Devices can be registered with W&T via the inventory tool. In
the event of security-relevant updates and/or information, we
will notify you immediately by email. In addition to the perso-
nal data provided, device-specific data is also stored during
registration.
11�1�5 Operation and configuration
Individuelles Geräte-Zertifikat
Web-based management can only be accessed in encrypted
form via HTTPS. A device-specific, self-signed default certifica-
te is used ex works for this purpose, for which an exception
must be set up in the browser used during commissioning.
For access during operation, we recommend replacing the de-
fault certificate with your own individual certificate to protect
against man-in-the-middle attacks.
Summary of Contents for 55211
Page 6: ...W T ...
Page 7: ...7 W T Subject to error and alteration 1 Legal information and safety ...
Page 12: ...12 W T ...
Page 56: ...56 W T Operation modes and rule configuration ...
Page 80: ...80 W T WireGuard VPN client ...
Page 84: ...84 W T WireGuard VPN Box to Box ...
Page 111: ...111 W T Subject to error and alteration Appendix Technical data and form factor ...