65
Subject to errors and modifications
W&T
Appendix
7.4 Reset to factory defaults
The USB-Server can be reset to its factory default settings using
the following methods.
7.4.1 Hardware reset to factory default settings
To use this method the motherboard of the USB-Server has a
jumper next to the network port. This is OUT for standard
mode.
Put this jumper IN and then connect power to the USB-Server.
After approx. 15 seconds the four LEDs
USB Connect
and
USB
Error
flash cyclically. The USB-Server is now reset to its factory
default settings and is ready to use again after removing the
jumper and after a reset.
Opening the housing
First disconnect all cables from the USB-Server. Open the DIN
rail mount housing by gently pressing on the narrow sides of
the housing. The housing cover can now be removed and the
board removed from the housing body.
7.4.2 Software reset to factory default settings
In addition to the hardware method, the USB-Server can also be
restored to its factory default settings using Web-Based-Ma-
nagement. After Login the
Restore Factory Defaults
button is
visible in the
Logout
menu branch.