MAINTENANCE ISTRUCTIONS FOR THE SAFETY VALVE 

(WATER BLOCK

®

 

WATER BLOCK (WB)  SAFETY VALVE  

Indispensable device for washing machines, dishwashers and demineralizers as, under the conditions defined in the technical 
features herewith described, it prevents a flow of water greater than the one for which it has been set by the adjustment 
pointer. This avoids continuous leaking. The Water Block also has a particular non-return valve (antipollution). The device 
should be installed vertically (see fig. 2) and following the instructions carefully. 
 
TECHNICAL FEATURES 

-

 

Burst pressure: 500 

N/cm²

  

-

 

Max. static pressure: 100 

N/cm²

 

-

 

Max. controllable volume: about 50 lt. 

-

 

Min. operating capacity: 2 lt/min. 

-

 

Max. operating capacity: 30 lt/min 

-

 

Max. water temperature: 70° C 

 
USER INSTRUCTIONS 
WATER BLOCK should be installed between the tap and the supply hose of the 
demineralizer (fig. 2). Using the enclosed plastic key, turn pointer ‘P’ (fig. 1) 
anticlockwise to the required setting (example, position 1,5). 
 
CAUTION: 
For use on other fixtures, set the pointer to a position suitable for that particular application, considering that  each number on 
the scale corresponds to a controlled volume of approx. 4-6 litres. 
In case of installation on fixtures which foresee dispensing of drinking water for alimentary use it is advisable to let flow at least 
10 litres of water inside the device before the connection, so as remove eventual impurities banked during the storage. 
 
INSTALLATION 
1. 

Manually screw the WB to the tap having suitable thread (3/4” gas), 
inserting the filter ‘E’ with its convex side facing upwards (fig. 2). The 
WB will not operate properly if the filter is not installed correctly. If the 
WB is tightened or loosened with the aid of a wrench, the same must 
be applied to the appropriately octagonally shaped part of the housing 
‘A’. 

2. 

Screw the supply hose ‘C’ to the lower end of the WB. If the supply 
hose is equipped with a filter, the latter must be substituted by a flat 
rubber washer ‘F’. If the said hose has to be tightened or loosened with 
the aid of a wrench, the same must be applied to the appropriately 
octagonally shaped part of the WB housing ‘B’ so as to hold it firmly 
while performing this operation. 
If a failure occurs causing a continuous water leak, the WB will shut off 
when the volume of water flowing through equals the amount to which it 
was previously set with the pointer ‘P’. 
To reset the Water Block again after it has shut off, turn the tap off and 
carry out the necessary repair work. Remove the supply hose ‘C’ from 
the Water Block and press the coloured plunger ‘H’ which is located 
inside the lower housing of the device itself (fig. 1). It may be difficult to 
press this plunger if there is high pressure at the inlet side of the WB. In 
this case, slacken the device from the tap: the plunger ‘H’ can then be 
pressed with ease. Repeat the operation as described in the section 
headed ‘Installation’. 

 
CAUTION: 
To avoid any possible damage that may be caused by water freezing inside 
the WB after its installation, the ambient temperature should never be below 
2° C. We decline all responsibility deriving from th e incorrect use of the WB 
or from its use for applications and/or solutions not expressly foreseen by the 
above instructions. 
 
MAINTENANCE: 
Depending on the conditions and frequency of usage of the water block, it is  recommended to 
clean out the inlet filter ‘E’ periodically and to replace the seal ‘F’ .We reserve the right to modify any 
features without prior notice.

 

Fig. 1 

Produced by 
ELTEK s.p.a. 
Tel. 0142 335511 
Fax 0142 335555 
15033 Casale Monf. (Italy) 
[email protected] 

Summary of Contents for Osmo

Page 1: ...y it is necessary to read this manual carefully All our products comply with the current safety norms and do not involve any risk for the operator when used according to the instructions provided Whil...

Page 2: ...NAMEPLATE 8 SYSTEM COMPONENTS 8 PRELIMINARY INSTALLATION INSTRUCTIONS 9 INSTALLATION 10 PRIMING 12 EXAMPLES OF USAGE 13 USE AND OPERATION OF THE DEMINERALIZER 14 PRECAUTIONS TO AVOID WATER CONTAMINAT...

Page 3: ...ing and servicing the equipment in accordance with the instructions listed in this manual Only use genuine manufacturer resin cartridges dedicated for this product Do not drink the water produced by O...

Page 4: ...irritation due to the abrasive effect of the granules First aid procedures Skin contact The product cannot be absorbed by the skin Can provoke dehydration or mild irritation due to the abrasive effect...

Page 5: ...case of disputes the date on the delivery note relating to the equipment serial number will be valid The warranty does not cover defects or damage caused by Incorrect installation Inadequate maintenan...

Page 6: ...the package and keep it in case of future needs Open the package and check that the contents correspond to the delivery note there is no evidence of any damage In the event of damage or missing items...

Page 7: ...ube with spray gun 2 9 litre storage tank with a tap theoretic volume 13 19 litres actual volume 9 10 litres 3 Power Supply transformer 240Vac 24 Vdc 4 Water Block valve with filter and setting key wi...

Page 8: ...Resin filter cartridge Pressure control switch Storage tank One way valve Tap optional Spray gun SAT optional Power supply unit Model name Serial number Working pressure Country of manufacture Read t...

Page 9: ...n nearby to dispose the wastewater discarded by the osmotic membrane max 1 5m WB Valve The safety valve Water Block is fitted with a special one way valve which prevents the return of water into the h...

Page 10: ...all the holders A B C Connect the water block group and one way valve to the water network tap Insert the tube into the fitting and tighten with a ring nut Connect the tube to the pump s inlet fittin...

Page 11: ...older Insert the supplied red draining tube on the fitting and tighten with a ring nut Position the tube in a draining sink or a collecting basin A B C Open the devices tap Connect the transformer s 2...

Page 12: ...lug hole Figure 4 Example of installation Connection to Spray gun tap optional SAT optional ATTENTION After setting up the system it takes 5 minutes to produce demineralized water It takes approx 140...

Page 13: ...re 5 Possible uses of the device Manual use with spray gun standard for manual filling of the sterilizer tank and washing of instruments Automatic use to fill the sterilizer using the SAT option Manua...

Page 14: ...ith the pressure control switch set to 3 bar PRECAUTIONS TO AVOID WATER CONTAMINATION CAUTION In accordance with subsection 4 5 of EN1717 in order to avoid water quality degradation and bacterial grow...

Page 15: ...he performance of the product In the event of unexpected contamination of the water coming into the system for example the presence of soil all the cartridges can get damaged Replace the intermediate...

Page 16: ...t the use in unsuitable conditions can drastically reduce this In order to replace the membrane first unplug the power supply and close the water inlet and the storage tank valve Proceed as shown in t...

Page 17: ...of EN1717 have the Water Block and the one way valve checked at least once a year in case a sterilizer is attached to the system this could be done during the scheduled maintenance visits for the ste...

Page 18: ...LOCK CARTRIDGE A813016X 5 RESIN CARTRIDGE A813017X 6 OSMOTIC MEMBRANE 75 GPM 95 98 REJECTION A813018X 7 O RING A813014X 8 PLASTIC KEY FOR CARTRIDGE HOLDER A812101X 9 STORAGE TANK INCLUDING TAP A813007...

Page 19: ...U382016X 16 MANOSTAT AND WIRING KIT A813011X 17 ONE WAY VALVE A812116X 18 UV KIT A813012X 19 KIT WATER TAP A813013X 20 WATER PIPE 5 m 6 35 mm A813020X 21 PRESSURE REDUCER X 3 BAR A813025X 22 CATRIDGE...

Page 20: ...t of the storage tank 3 5 kg Tank nominal volume 19 liters Tank storable volume ca 9 liters Electric power supply 100 240 VAC 50 60 Hz 1 0A with separate voltage transformer Max absorbed power 40 W Cl...

Page 21: ...ened with the aid of a wrench the same must be applied to the appropriately octagonally shaped part of the housing A 2 Screw the supply hose C to the lower end of the WB If the supply hose is equipped...